Hindi
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical and Bioanalytical Chemistry 2015-Sep

Ultrasensitive microfluidic array for serum pro-inflammatory cytokines and C-reactive protein to assess oral mucositis risk in cancer patients.

केवल पंजीकृत उपयोगकर्ता ही लेखों का अनुवाद कर सकते हैं
साइन अप करने के लिए लॉग इन करें
लिंक क्लिपबोर्ड पर सहेजा गया है
Colleen E Krause
Brunah A Otieno
Gregory W Bishop
Gayatri Phadke
Linda Choquette
Rajesh V Lalla
Douglas E Peterson
James F Rusling

कीवर्ड

सार

In addition to disease diagnostics, there is a need for biomarkers to predict severity of cancer therapy side effects such as oral mucositis. Oral mucositis is an inflammatory lesion of oral mucosa caused by high-dose chemotherapy and/or radiation that is especially prevalent during oral cancer treatment. We describe here a semi-automated, modular microfluidic immunoarray optimized for ultrasensitive detection of pro-inflammatory cytokines involved in pathobiology of oral mucositis. Our goal is to methodologically identify risk of mucositis early in oral cancer treatment, before the onset of lesions. Biomarkers include tumor necrosis factor alpha (TNF-α), interleukin-6 (IL-6), interleukin-1β (IL-1β), and C-reactive protein (CRP). Protein analytes were captured from serum in a capture chamber by 1-μm magnetic beads coated with antibodies and enzyme labels. Beads are then transported downstream to a detection chamber containing an eight-sensor array coated with glutathione-coated gold nanoparticles (GSH-AuNP) and a second set of antibodies to capture the beads with analyte proteins. In this first application of the immunoarray to four-protein multiplexed measurements, ultralow detection limits of 10-40 fg mL(-1) in 5 μL serum were achieved for simultaneous detection in 30 min. Mass detection limits were 2.5-10 zmol, as few as 1500 molecules. Accuracy and diagnostic utility of the arrays were demonstrated by correlation of levels of the four biomarker proteins in serum from head and neck cancer patients with results from standard ELISA. This approach may lead to rapid, low-cost estimates of projected risk for severity of oral mucositis in cancer patients to enable improved therapeutic management.

हमारे फेसबुक पेज से जुड़ें

विज्ञान द्वारा समर्थित सबसे पूर्ण औषधीय जड़ी बूटी डेटाबेस

  • 55 भाषाओं में काम करता है
  • विज्ञान द्वारा समर्थित हर्बल इलाज
  • छवि द्वारा जड़ी बूटी की मान्यता
  • इंटरएक्टिव जीपीएस नक्शा - स्थान पर टैग जड़ी बूटियों (जल्द ही आ रहा है)
  • अपनी खोज से संबंधित वैज्ञानिक प्रकाशन पढ़ें
  • उनके प्रभाव से औषधीय जड़ी बूटियों की खोज करें
  • अपने हितों को व्यवस्थित करें और समाचार अनुसंधान, नैदानिक परीक्षणों और पेटेंट के साथ अद्यतित रहें

एक लक्षण या बीमारी टाइप करें और जड़ी-बूटियों के बारे में पढ़ें जो मदद कर सकती हैं, एक जड़ी बूटी टाइप करें और बीमारियों और लक्षणों को देखें जिनके खिलाफ इसका उपयोग किया जाता है।
* सभी जानकारी प्रकाशित वैज्ञानिक शोध पर आधारित है

Google Play badgeApp Store badge