A 3D-printed metal column for micro gas chromatography

केवल पंजीकृत उपयोगकर्ता ही लेखों का अनुवाद कर सकते हैं
साइन अप करने के लिए लॉग इन करें
लिंक क्लिपबोर्ड पर सहेजा गया है
Sooyeol Phyo
Sung Choi
Jaeheok Jang
Sun Choi
Jiwon Lee

कीवर्ड

सार

In this work, a 3D-printed metal column was developed for micro gas chromatography (GC) applications and its properties and gas separation performances were characterized. By using a Ti6Al4V grade 23 powder, a square spiral one meter-long column (3D-column) was 3D-printed on a planar substrate of 3.4 × 3.3 × 0.2 cm and then perhydropolysilazane (PHPS) was deposited as a pre-treatment agent, followed by a coating of stationary phase (OV-1) onto the inner wall of the micro-channel. The 500 μm-diameter circular channel and two 800 μm-wide ports of the 3D-column were confirmed to be uniform by 3D X-ray microscopy without any distortion. The physical and thermal properties of the 3D-column were found to be very similar to that of the standard Ti6Al4V grade 23 alloy with near zero porosity (∼0.07%). The 3D-column with pre-treatment and stationary coating demonstrated efficient separation performance of gas mixtures containing alkanes, aromatics, alcohols, and ketones compared to a bare or only pretreated 3D-column in terms of the peak shape, broadening, and resolution (R > 1) within 2-3 min. The well-matched thermal responses to the target temperatures were demonstrated at the ramping rates of 10-20 °C min-1 upto 200 °C with uniform heat distribution over the 3D-column. In addition, the column bleed profiles showed that the 3D-column with PHPS had a 71% lower baseline intensity at 350 °C than that without PHPS. The 3D-column was then employed to separate a gas mixture of twelve alkanes (C9-C18, C22, C24) without any significant column bleeding and peak tailing. Therefore, the thermal responses and stability of the 3D-column promise its applicability in high temperature GC applications.

हमारे फेसबुक पेज से जुड़ें

विज्ञान द्वारा समर्थित सबसे पूर्ण औषधीय जड़ी बूटी डेटाबेस

  • 55 भाषाओं में काम करता है
  • विज्ञान द्वारा समर्थित हर्बल इलाज
  • छवि द्वारा जड़ी बूटी की मान्यता
  • इंटरएक्टिव जीपीएस नक्शा - स्थान पर टैग जड़ी बूटियों (जल्द ही आ रहा है)
  • अपनी खोज से संबंधित वैज्ञानिक प्रकाशन पढ़ें
  • उनके प्रभाव से औषधीय जड़ी बूटियों की खोज करें
  • अपने हितों को व्यवस्थित करें और समाचार अनुसंधान, नैदानिक परीक्षणों और पेटेंट के साथ अद्यतित रहें

एक लक्षण या बीमारी टाइप करें और जड़ी-बूटियों के बारे में पढ़ें जो मदद कर सकती हैं, एक जड़ी बूटी टाइप करें और बीमारियों और लक्षणों को देखें जिनके खिलाफ इसका उपयोग किया जाता है।
* सभी जानकारी प्रकाशित वैज्ञानिक शोध पर आधारित है

Google Play badgeApp Store badge