Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2017-Sep

Fully international system of units-traceable glycated hemoglobin quantification using two stages of isotope-dilution high-performance liquid chromatography-tandem mass spectrometry.

Samo registrirani korisnici mogu prevoditi članke
Prijava Registriraj se
Veza se sprema u međuspremnik
Thi Thanh Huong Tran
Jinsook Lim
Juok Kim
Ha-Jeong Kwon
Gye Cheol Kwon
Ji-Seon Jeong

Ključne riječi

Sažetak

Glycated hemoglobin (HbA1c), defined as hemoglobin (Hb) molecules having a stable adduct of glucose on the N-terminal of the β-chains, has been endorsed as a diagnostic tool for diabetes mellitus and a prediction indicator for the development of diabetes complications. Here we describe an accurate procedure using two stages of isotope dilution-ultra performance liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) for the quantification of HbA1c that provides full traceability to International System of Units (SI). First, synthetic peptides representing specific markers of HbA1c (G-hexa) and hemoglobin A0 (Hexa) were certified by amino acid analysis via acid hydrolysis as reference materials (RMs) for the next step. For this peptide certification, three amino acids (proline, valine, and leucine) were determined by hydrolysis with 10M hydrochloric acid at 130°C for 48h followed by ID-LC-MS/MS. Then, HbA1c content in blood was quantified with the ratio of specific proteolytic peptides from HbA1c and HbA0 via enzyme digestion using ID-LC-MS/MS with the certified peptides as RMs and isotope-labeled peptides as internal standards. Results demonstrate complete traceability to SI-units throughout this procedure. Reliability was confirmed through comparative studies with commercially available RMs for HbA1c, and other routine HbA1c diagnostic methods as well. Following full method validation, we applied this procedure to the certification of candidate hemolysate-certified RMs for HbA1c content, as well as 52 real clinical samples. All of the results showed the suitability of this method to act as a primary reference measurement procedure for HbA1c in complex biological samples.

Pridružite se našoj
facebook stranici

Najkompletnija baza ljekovitog bilja potpomognuta znanošću

  • Radi na 55 jezika
  • Biljni lijekovi potpomognuti znanošću
  • Prepoznavanje bilja slikom
  • Interaktivna GPS karta - označite bilje na mjestu (uskoro)
  • Pročitajte znanstvene publikacije povezane s vašom pretragom
  • Pretražite ljekovito bilje po učincima
  • Organizirajte svoje interese i budite u toku s istraživanjem vijesti, kliničkim ispitivanjima i patentima

Upišite simptom ili bolest i pročitajte o biljkama koje bi mogle pomoći, unesite travu i pogledajte bolesti i simptome protiv kojih se koristi.
* Svi podaci temelje se na objavljenim znanstvenim istraživanjima

Google Play badgeApp Store badge