Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Pharmaceutical and Biomedical Analysis 2005-Feb

Uniformly sized molecularly imprinted polymer for atropine and its application to the determination of atropine and scopolamine in pharmaceutical preparations containing Scopolia extract.

Samo registrirani korisnici mogu prevoditi članke
Prijava Registriraj se
Veza se sprema u međuspremnik
Masanori Nakamura
Masaki Ono
Toshiaki Nakajima
Yuji Ito
Takao Aketo
Jun Haginaka

Ključne riječi

Sažetak

A uniformly sized molecularly imprinted polymer (MIP) for atropine has been prepared. The MIP was prepared using 2-(trifluoromethyl) acrylic acid and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and thermal polymerization method. The selectivity factor, which is defined as the ratio of the retention factors (k) on the molecularly imprinted and non-imprinted polymers, k(imprinted)/k(non-imprinted), was 2.2 for atropine on the MIP. The obtained MIP was applied for the determination of tropane alkaloids (atropine and scopolamine) in a commercial gastrointestinal drug by a column-switching HPLC system, consisting of an MIP material as a pre-column, and a conventional cation-exchange analytical column. An interference peak was observed at the retention time of atropine derived from pre-column. However, since the peak area was less than 0.5% the peak area of atropine of a standard solution under the analytical conditions of this study (0.2 microg of atropine was loaded), this interference was negligible in the determination of atropine. On the other hand, no interference peak was observed at the retention time of scopolamine. Calibration curves of atropine and scopolamine showed good linearity in the range of 0.02-0.9 microg/ml (r=0.9999) and 0.003-0.09 microg/ml (r=0.9998), respectively. The mean recoveries of atropine and scopolamine from a placebo pharmaceutical preparation sample were 98.9 and 99.9%, respectively. The intra-day precision (measured by relative standard deviation, R.S.D. (%)) of both ingredients was less than 2.0%. The optimized column-switching system was applied successfully to the determination of atropine and scopolamine in a commercial gastrointestinal drug.

Pridružite se našoj
facebook stranici

Najkompletnija baza ljekovitog bilja potpomognuta znanošću

  • Radi na 55 jezika
  • Biljni lijekovi potpomognuti znanošću
  • Prepoznavanje bilja slikom
  • Interaktivna GPS karta - označite bilje na mjestu (uskoro)
  • Pročitajte znanstvene publikacije povezane s vašom pretragom
  • Pretražite ljekovito bilje po učincima
  • Organizirajte svoje interese i budite u toku s istraživanjem vijesti, kliničkim ispitivanjima i patentima

Upišite simptom ili bolest i pročitajte o biljkama koje bi mogle pomoći, unesite travu i pogledajte bolesti i simptome protiv kojih se koristi.
* Svi podaci temelje se na objavljenim znanstvenim istraživanjima

Google Play badgeApp Store badge