Haitian Creole
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2018-May

Development of a micro-solid-phase extraction molecularly imprinted polymer technique for synthetic cannabinoids assessment in urine followed by liquid chromatography-tandem mass spectrometry.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Lyen an sove nan clipboard la
Juan Sánchez-González
Sara Odoardi
Ana María Bermejo
Pilar Bermejo-Barrera
Francesco Saverio Romolo
Antonio Moreda-Piñeiro
Sabina Strano-Rossi

Mo kle

Abstrè

Several molecularly imprinted polymers (MIPs) have been synthesized for the first time using various synthetic cannabinoids (JWH007, JWH015 and JWH098) as template molecules. Ethylene dimethacrylate (EDMA) was used as a functional monomer for all cases. Similarly, divinylbenzene (DVB) and 2,2'-azobisisobutyronitrile (AIBN) were used as cross-linker and initiator, respectively. The prepared MIPs have been fully characterized and evaluated as new selective adsorbents for micro-solid phase extraction (μ-SPE) of synthetic cannabinoids in urine. The developed MIP-μ-SPE devices consisted of a polypropylene (PP) porous membrane containing the adsorbent (novel porous membrane protected micro-solid phase extraction based on a cone-shaped device) for operating in batch mode, which allowed a fast and integrated extraction-cleanup procedure. High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was used for quantifying the analytes after MIP-μ-SPE. The best performances were obtained for MIPs prepared from JWH015 as a template. Optimum loading conditions were found to be urine pH of 5.0 and adsorption time of 8.0 min under mechanical (orbital-horizontal) stirring at 100 rpm. The composition of the eluting solution consisted of 75:20:5 heptane/2-propanol/ammonium hydroxide. The elution was assisted by ultrasounds (37 kHz, 325 W) for 8.0 min. In addition, studies regarding selectivity have also been addressed for several drugs of abuse under optimized loading/adsorption conditions. Validation of the method showed good precision and analytical recovery by intra-day and inter-day assays (RSD values lower than 7 and 10% for intra-day and inter-day precision, and within the 83-100% range for intra-day and inter-day analytical recovery).

Antre nan paj
facebook nou an

Baz done ki pi konplè remèd fèy medsin te apiye nan syans

  • Travay nan 55 lang
  • Geri èrbal te apiye nan syans
  • Remèd fèy rekonesans pa imaj
  • Kat entèaktif GPS - tag zèb sou kote (vini byento)
  • Li piblikasyon syantifik ki gen rapò ak rechèch ou an
  • Search remèd fèy medsin pa efè yo
  • Izeganize enterè ou yo ak rete kanpe fè dat ak rechèch la nouvèl, esè klinik ak rive

Tape yon sentòm oswa yon maladi epi li sou remèd fèy ki ta ka ede, tape yon zèb ak wè maladi ak sentòm li itilize kont.
* Tout enfòmasyon baze sou rechèch syantifik pibliye

Google Play badgeApp Store badge