Journal of the American College of Cardiology 1994-May

Improved endocardial border resolution during dobutamine stress echocardiography with intravenous sonicated dextrose albumin.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Lyen an sove nan clipboard la
T R Porter
F Xie
A Kricsfeld
A Chiou
A Dabestani

Mo kle

Abstrè

OBJECTIVE

The purpose of this study was to determine whether intravenous sonicated dextrose albumin could improve endocardial border resolution during dobutamine stress echocardiography.

BACKGROUND

Sonicated albumin improves endocardial border resolution in patients undergoing exercise stress echocardiography. Because a sonicated mixture of albumin with dextrose results in better transpulmonary passage than sonicated albumin alone, this agent could be utilized to further improve endocardial border resolution during dobutamine stress echocardiography.

METHODS

We gave intravenous injections of sonicated dextrose and albumin to 50 patients undergoing dobutamine stress echocardiography. Left ventricular video intensity, contrast agent persistence (in seconds), number of contrast agent-enhanced cardiac cycles and improvement in endocardial border resolution were assessed from the apical four-chamber view at baseline, low dose (10 micrograms/kg body weight per min) and peak dobutamine infusion.

RESULTS

There was significantly better left ventricular peak video intensity at peak dobutamine infusion than after the same injection at baseline (p < 0.005, analysis of variance). The number of contrast agent-enhanced cardiac cycles in the left ventricular cavity was also significantly longer at peak infusion. Endocardial border resolution was improved (mainly in lateral segments) in 93% of patients at low dose and 95% of patients at peak infusion.

CONCLUSIONS

Intravenous sonicated dextrose albumin improves endocardial border resolution during dobutamine stress echocardiography.

Antre nan paj
facebook nou an

Baz done ki pi konplè remèd fèy medsin te apiye nan syans

  • Travay nan 55 lang
  • Geri èrbal te apiye nan syans
  • Remèd fèy rekonesans pa imaj
  • Kat entèaktif GPS - tag zèb sou kote (vini byento)
  • Li piblikasyon syantifik ki gen rapò ak rechèch ou an
  • Search remèd fèy medsin pa efè yo
  • Izeganize enterè ou yo ak rete kanpe fè dat ak rechèch la nouvèl, esè klinik ak rive

Tape yon sentòm oswa yon maladi epi li sou remèd fèy ki ta ka ede, tape yon zèb ak wè maladi ak sentòm li itilize kont.
* Tout enfòmasyon baze sou rechèch syantifik pibliye

Google Play badgeApp Store badge