Clinical and Vaccine Immunology 2008-Jan

Rapid, sensitive, and specific lateral-flow immunochromatographic point-of-care device for detection of herpes simplex virus type 2-specific immunoglobulin G antibodies in serum and whole blood.

Se sèlman itilizatè ki anrejistre yo ki ka tradwi atik yo
Log In / Enskri
Lyen an sove nan clipboard la
Elisabeth I Laderman
Emma Whitworth
Erickson Dumaual
Mark Jones
Andrew Hudak
Wayne Hogrefe
Jim Carney
Jan Groen

Mo kle

Abstrè

Herpes simplex virus type 2 (HSV-2) is a common human pathogen that can cause a variety of clinical manifestations in humans. In order to provide near-patient results to allow for faster counseling and treatment, a rapid point-of-care test that is accurate and simple to use is desirable. Here, we describe the development and evaluation of an HSV-2 immunoglobulin G (IgG)-specific antibody lateral-flow immunochromatographic assay (LFIA) based on colloidal gold nanoparticles. A total of 359 serum samples and 100 whole-blood samples were tested in the newly developed HSV-2 LFIA. Serum results were compared to those from the HerpeSelect HSV-2 enzyme-linked immunosorbent assay (ELISA), and whole-blood sample results were compared to those of both ELISA and HerpeSelect HSV-1 and -2 immunoblotting (IB). The sensitivity of the HSV-2 LFIA compared to that of the HerpeSelect ELISA was 100% (89/89), and the specificity was 97.3% (257/264). Cross-reactivity with HSV-1 IgG-positive serum samples was observed in 2.6% (5/196) of samples, 2.9% (1/34) for rubella virus, and 6.2% (1/16) for Epstein-Barr virus. No cross-reactivity in varicella-zoster virus or cytomegalovirus IgG-positive serum samples was observed. No interference was observed from bilirubin-, triglyceride-, albumin-, or hemoglobin-spiked samples. The concordance of the LFIA results between capillary whole blood, EDTA-treated venous whole blood, heparin-treated venous whole blood, and serum was 99% (99/100). In conclusion, the LFIA for HSV-2 IgG-specific antibodies demonstrated excellent sensitivity, specificity, and concordance for both serum and whole-blood samples compared to the sensitivity, specificity, and concordance of both HSV-2 ELISA and IB.

Antre nan paj
facebook nou an

Baz done ki pi konplè remèd fèy medsin te apiye nan syans

  • Travay nan 55 lang
  • Geri èrbal te apiye nan syans
  • Remèd fèy rekonesans pa imaj
  • Kat entèaktif GPS - tag zèb sou kote (vini byento)
  • Li piblikasyon syantifik ki gen rapò ak rechèch ou an
  • Search remèd fèy medsin pa efè yo
  • Izeganize enterè ou yo ak rete kanpe fè dat ak rechèch la nouvèl, esè klinik ak rive

Tape yon sentòm oswa yon maladi epi li sou remèd fèy ki ta ka ede, tape yon zèb ak wè maladi ak sentòm li itilize kont.
* Tout enfòmasyon baze sou rechèch syantifik pibliye

Google Play badgeApp Store badge