Hungarian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Clinical Microbiology 2000-Feb

Comparison of sorbitol MacConkey agar and a two-step method which utilizes enzyme-linked immunosorbent assay toxin testing and a chromogenic agar to detect and isolate enterohemorrhagic Escherichia coli.

Csak regisztrált felhasználók fordíthatnak cikkeket
Belépés Regisztrálás
A hivatkozás a vágólapra kerül
T J Novicki
J A Daly
S L Mottice
K C Carroll

Kulcsszavak

Absztrakt

Enterohemorrhagic Escherichia coli (EHEC) and specifically serotype O157:H7 are a significant cause of hemorrhagic gastrointestinal disease and the hemolytic uremic syndrome. Methods currently used in clinical microbiology labs, such as sorbitol-MacConkey (SMAC) agar, reliably detect only O157:H7. We have evaluated a two-step method that has the potential to identify and isolate all EHEC serotypes, including serotype O157:H7. This method utilizes a chromogenic selective-differential medium for the isolation of E. coli together with an enzyme-linked immunosorbent assay (ELISA) that detects the Shiga-like toxins Stx1 and Stx2. Both are commercially available and usable in a wide range of clinical microbiology laboratories. Compared to a Vero cell cytotoxic assay, SMAC had sensitivities of 23.5% for the identification of all EHEC serotypes and of 50.0% for the identification of O157:H7 alone. The two-step method had sensitivities of 76.5 and 100%, respectively. The ELISA alone had a sensitivity of 82.4% in the detection of Stx1 and Stx2. The specificity was 100% in all cases. Overall, 14 EHEC isolates were obtained: 8 (58%) O157:H7, 2 (14%) O26, 2 (14%) O111:NM, 1 (7%) O103:H2, and 1 (7%) O121:H19. All but one were isolated during the months of May to September. The two-step method was found to be considerably more expensive than SMAC for both positive and negative samples.

Csatlakozzon
facebook oldalunkhoz

A legteljesebb gyógynövény-adatbázis, amelyet a tudomány támogat

  • Működik 55 nyelven
  • A tudomány által támogatott gyógynövényes kúrák
  • Gyógynövények felismerése kép alapján
  • Interaktív GPS térkép - jelölje meg a gyógynövényeket a helyszínen (hamarosan)
  • Olvassa el a keresésével kapcsolatos tudományos publikációkat
  • Keresse meg a gyógynövényeket hatásuk szerint
  • Szervezze meg érdeklődését, és naprakész legyen a hírkutatással, a klinikai vizsgálatokkal és a szabadalmakkal

Írjon be egy tünetet vagy betegséget, és olvassa el azokat a gyógynövényeket, amelyek segíthetnek, beírhat egy gyógynövényt, és megtekintheti azokat a betegségeket és tüneteket, amelyek ellen használják.
* Minden információ publikált tudományos kutatáson alapul

Google Play badgeApp Store badge