Hungarian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Environmental Science and Health - Part A Toxic/Hazardous Substances and Environmental Engineering 2008-Apr

Evaluation of nitrobenzenes and chlorobenzenes levels in samples of sediments from Italy: a rapid and simple method by automatic extractor and GC/MS ion trap.

Csak regisztrált felhasználók fordíthatnak cikkeket
Belépés Regisztrálás
A hivatkozás a vágólapra kerül
Angela Santilio
Giovanni Ziemacki
Patrizia Stefanelli
Roberto Dommarco

Kulcsszavak

Absztrakt

Ninety-six marine sediment samples from an Italian harbour were analysed by GC/MS ion trap for the residues of nitrobenzenes and chlorobenzenes. The significance of these compounds in the investigated matrix was discussed. In order to determine the simultaneous presence of chlorobenzenes and nitrobenzenes in marine sediments, a simple extraction method by an automatic extraction system was developed. The use of an automatic extractor unit allows the extraction of the analytes of interest with no waste of volatile compounds, since small volumes of solvent are required. This also results in a reduction of the analysis time, compared with traditional extraction techniques such as extraction by Soxhlet. The samples under investigation were mixed with anhydrous sodium sulphate to obtain a free-flowing powder and quantitatively transferred into extraction thimbles. The thimbles were then introduced into the automatic extractor unit by solvent and extracted with 70 mL of acetone/hexane (1:1, v/v). The extract was analysed directly by GC/MS ion trap in EI mode. A VF5 ms low bleeding capillary column was used to separate the compounds of interest. Recovery rates were determined at two spiking levels, one ranging from 1.0 to 5.0 mg/kg, the other from 10 to 50 mg/kg. Six replicates were analysed for each fortification level. Mean recoveries proved to range from 60.6 to 125.1% in either case. The precision of the method was expressed as relative standard deviation (RSD%), which turned out to be in the range 5.2-15.0%. The determination limits ranged from 0.01 mg/kg to 1.0 mg/kg, when approximately 10 g (dry weight) samples were considered. The linearity (r(2) > 0.99) and the limit of detection were also studied.

Csatlakozzon
facebook oldalunkhoz

A legteljesebb gyógynövény-adatbázis, amelyet a tudomány támogat

  • Működik 55 nyelven
  • A tudomány által támogatott gyógynövényes kúrák
  • Gyógynövények felismerése kép alapján
  • Interaktív GPS térkép - jelölje meg a gyógynövényeket a helyszínen (hamarosan)
  • Olvassa el a keresésével kapcsolatos tudományos publikációkat
  • Keresse meg a gyógynövényeket hatásuk szerint
  • Szervezze meg érdeklődését, és naprakész legyen a hírkutatással, a klinikai vizsgálatokkal és a szabadalmakkal

Írjon be egy tünetet vagy betegséget, és olvassa el azokat a gyógynövényeket, amelyek segíthetnek, beírhat egy gyógynövényt, és megtekintheti azokat a betegségeket és tüneteket, amelyek ellen használják.
* Minden információ publikált tudományos kutatáson alapul

Google Play badgeApp Store badge