Armenian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Radiation and Environmental Biophysics 1987

Analytical techniques for boron and boron 10 analysis in a solid experimental tumor EO. 771.

Միայն գրանցված օգտվողները կարող են հոդվածներ թարգմանել
Մուտք / Գրանցվել
Հղումը պահվում է clipboard- ում
W Porschen
J Marx
F Dallacker
H Mückter
T Böhmel
R Fairchild
L E Feinendegen

Հիմնաբառեր

Վերացական

If a tumor can be preferentially loaded with a suitable boron-10 compound and irradiated with thermal neutrons, malignant cells can be selectively destroyed via the alpha-particle + Li 7-nucleus from the reaction 10B(n, alpha)7Li. Neutron capture therapy with two boron-10 amino acid analogs of low toxicity has been tested in recent years: (a) trimethylamine-carboxyborane, (A3) and (b) amine-carboxyborane, (A7). Now the boron-10 glycineamide analog (A8), amineboryl-carboxamide has been synthesized; it contains 13.81% boron (90% Boron 10 + 10% Boron 11) and shows a very low toxicity in mice. The effects of this compound were tested on the syngeneic solid adenocarcinoma EO 771 on the right hind leg of male C57 BL/6J mice under standard conditions, by measuring tumor volume growth delay and cell cycle changes using flow cytometry. Boron distribution between tumor and muscle was analyzed by emission spectroscopy with inductively coupled plasma (ICP) following injection of a suspension of peanut oil emulsion. In addition, boron-10 concentration in the tumor were analyzed with prompt gamma-activation analysis and neutron capture radiography (Kodak-Pathé LR 115) at the MRR reactor in Brookhaven after i.p. injection of 0.4 mg/g A8. Application of A8 alone (0.4 mg/g i.p.) or thermal neutron irradiation of the tumor EO. 771 produced a tumor growth delay of 1-2 days for tumor volume doubling. Application of the boron 10 glycine-amide analog A8 i.p. plus 5 X 10(12)n/cm2 resulted in a growth delay of 3-6 days. In contrast intratumoral application of A8 plus 4 X 10(12)n/cm2 neutrons gave a growth delay of 7-14 days; the fraction of (G2 + M) cells rose from 35% (neutrons alone) to 52%, as evaluated from flow cytometry.

Միացեք մեր
ֆեյսբուքյան էջին

Բժշկական դեղաբույսերի ամենալավ տվյալների շտեմարանը, որին աջակցում է գիտությունը

  • Աշխատում է 55 լեզուներով
  • Բուսական բուժում, որին աջակցում է գիտությունը
  • Խոտաբույսերի ճանաչում պատկերով
  • Ինտերակտիվ GPS քարտեզ - նշեք խոտաբույսերը գտնվելու վայրի վրա (շուտով)
  • Կարդացեք ձեր որոնմանը վերաբերող գիտական հրապարակումները
  • Որոնեք բուժիչ դեղաբույսերը ՝ դրանց ազդեցությամբ
  • Կազմակերպեք ձեր հետաքրքրությունները և մշտապես տեղեկացեք նորությունների հետազոտությունների, կլինիկական փորձարկումների և արտոնագրերի մասին

Մուտքագրեք ախտանիշ կամ հիվանդություն և կարդացեք խոտաբույսերի մասին, որոնք կարող են օգնել, տպեք խոտ և տեսեք այն հիվանդություններն ու ախտանիշները, որոնց դեմ օգտագործվում են:
* Ամբողջ տեղեկատվությունը հիմնված է հրապարակված գիտական հետազոտության վրա

Google Play badgeApp Store badge