Armenian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Ophthalmic Inflammation and Infection 2012-Jun

Macular sensitivity and fixation patterns in normal eyes and eyes with uveitis with and without macular edema.

Միայն գրանցված օգտվողները կարող են հոդվածներ թարգմանել
Մուտք / Գրանցվել
Հղումը պահվում է clipboard- ում
Yasir J Sepah
Elham Hatef
Elizabeth Colantuoni
Jianmin Wang
Mathew Shulman
Fatima Idrees Adhi
Abeer Akhtar
Mohamed Ibrahim
Afsheen Khwaja
Roomasa Channa

Հիմնաբառեր

Վերացական

OBJECTIVE

This study aims to investigate the relationship between macular sensitivity and thickness in eyes with uveitic macular edema (UME).

METHODS

This study is a prospective observational case series.

METHODS

The setting for this study was clinical practice. The study included 59 (28 with UME, 31 without UME) eyes of 26 patients with uveitis and 19 eyes of 10 normal subjects. The procedure followed was fundus-related perimetry and retinal thickness map with an automated fundus perimetry/tomography system. Main outcome measures included quantification of macular sensitivity, fixation pattern, and relationship between macular sensitivity and thickness.

RESULTS

Fixation stability revealed that 56 eyes (93.44%) had stable fixation (>75% within the central 2° of point of fixation); three eyes (6.56%) were relatively unstable (<75% of fixation points located within 2°, >75% located within 4°); and no eye had unstable fixation (<75% of fixation points located within 4°). Evaluation of fixation location revealed that 45 eyes (76.27%) had central fixation location (>50% of fixation point within 0.5 mm of foveal center); seven eyes (11.86%) had peri-central fixation location (25% << 50% within 0.5 mm); and seven eyes (11.86%) had eccentric (<25% of fixation point within 0.5 mm) fixation location. We measured macular sensitivity and corresponding thickness in 1,708 loci of 61 study eyes. Macular sensitivity increased by 0.02 dB (95% confidence interval, 0.00, 0.06) per 1 μm increase in the thickness for the thickness values ≤280 μm. Macular sensitivity decreased by 0.04 dB (95% CI, -0.08, -0.01) per 1 μm increase in the thickness for the thickness values >280 μm.

CONCLUSIONS

Perimetry quantification of macular sensitivity and retinal thickness, in association with other factors, may offer novel information regarding the impact of UME on retinal function.

Միացեք մեր
ֆեյսբուքյան էջին

Բժշկական դեղաբույսերի ամենալավ տվյալների շտեմարանը, որին աջակցում է գիտությունը

  • Աշխատում է 55 լեզուներով
  • Բուսական բուժում, որին աջակցում է գիտությունը
  • Խոտաբույսերի ճանաչում պատկերով
  • Ինտերակտիվ GPS քարտեզ - նշեք խոտաբույսերը գտնվելու վայրի վրա (շուտով)
  • Կարդացեք ձեր որոնմանը վերաբերող գիտական հրապարակումները
  • Որոնեք բուժիչ դեղաբույսերը ՝ դրանց ազդեցությամբ
  • Կազմակերպեք ձեր հետաքրքրությունները և մշտապես տեղեկացեք նորությունների հետազոտությունների, կլինիկական փորձարկումների և արտոնագրերի մասին

Մուտքագրեք ախտանիշ կամ հիվանդություն և կարդացեք խոտաբույսերի մասին, որոնք կարող են օգնել, տպեք խոտ և տեսեք այն հիվանդություններն ու ախտանիշները, որոնց դեմ օգտագործվում են:
* Ամբողջ տեղեկատվությունը հիմնված է հրապարակված գիտական հետազոտության վրա

Google Play badgeApp Store badge