Armenian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Rapid Communications in Mass Spectrometry 2010-Mar

Quantification of alkylresorcinols in human plasma by liquid chromatography/tandem mass spectrometry.

Միայն գրանցված օգտվողները կարող են հոդվածներ թարգմանել
Մուտք / Գրանցվել
Հղումը պահվում է clipboard- ում
Alastair B Ross
Karine Redeuil
Mario Vigo
Serge Rezzi
Kornél Nagy

Հիմնաբառեր

Վերացական

Alkylresorcinols (AR) are of interest as biomarkers of wholegrain wheat and rye intake in epidemiological studies and are currently mainly measured by gas chromatography/mass spectrometry (GC/MS) after labour-intensive sample preparation including liquid-liquid extraction, solid-phase extraction (SPE) and chemical derivatization. This manuscript describes and validates an alternative approach based on normal-phase liquid chromatography/tandem mass spectrometry for the quantification of alkylresorcinols in human plasma. The method requires neither SPE nor chemical derivatization and has a shortened run time compared to GC/MS. Normal- and reversed-phase columns and various mobile phases were evaluated with and without previous SPE of the samples. Normal-phase chromatography allowed separation of AR from the interfering triacylglycerols, diacylglycerols and sterols and enabled detection of AR even without SPE of the samples. The described method has instrumental lower limits of detection in the 25-75 pg range, and lower limits of quantification in the 75-250 pg range. Pooled human plasma and (2)H(4)-nonadecylresorcinol (internal standard) was applied to calibrate the method in the 20-12 000 nM range. The overall method showed intra-batch precision of 8.6% and an averaged accuracy of 100.2%. Applications for diverse human plasma samples are presented and are compared with the results determined by GC/MS. Based on the presented data; this method requiring less sample preparation is suggested for further evaluation as an alternative to GC/MS for analysis of biomarkers of wholegrain wheat and rye intake in epidemiological studies.

Միացեք մեր
ֆեյսբուքյան էջին

Բժշկական դեղաբույսերի ամենալավ տվյալների շտեմարանը, որին աջակցում է գիտությունը

  • Աշխատում է 55 լեզուներով
  • Բուսական բուժում, որին աջակցում է գիտությունը
  • Խոտաբույսերի ճանաչում պատկերով
  • Ինտերակտիվ GPS քարտեզ - նշեք խոտաբույսերը գտնվելու վայրի վրա (շուտով)
  • Կարդացեք ձեր որոնմանը վերաբերող գիտական հրապարակումները
  • Որոնեք բուժիչ դեղաբույսերը ՝ դրանց ազդեցությամբ
  • Կազմակերպեք ձեր հետաքրքրությունները և մշտապես տեղեկացեք նորությունների հետազոտությունների, կլինիկական փորձարկումների և արտոնագրերի մասին

Մուտքագրեք ախտանիշ կամ հիվանդություն և կարդացեք խոտաբույսերի մասին, որոնք կարող են օգնել, տպեք խոտ և տեսեք այն հիվանդություններն ու ախտանիշները, որոնց դեմ օգտագործվում են:
* Ամբողջ տեղեկատվությունը հիմնված է հրապարակված գիտական հետազոտության վրա

Google Play badgeApp Store badge