Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Archives of Pharmacal Research 2007-Oct

A liquid chromatographic method for the determination of histamine in immunoglobulin preparation using solid phase extraction and pre-column derivatization.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Nam Hee Kim
Youmie Park
Eun Sook Jeong
Chang-Soo Kim
Min Kyo Jeoung
Kyoung Soon Kim
Seung-Hwa Hong
Jong-Keun Son
Jin Tae Hong
Il-Young Park

Kata kunci

Abstrak

An immunoglobulin (IgG) preparation with micro-amount of histamine fixed on the active protein fraction has been used to increase the resistance to allergic reactions. However, excessive histamine may cause hypo- or hypertension, headache, or anaphylactic shock and so the histamine content of the drug is strictly controlled by a regulation: 0.15 microg of histamine dihydrochloride is allowed for 12 mg of immunoglobulin. In this study, a liquid chromatographic method to determine micro-amount of histamine in the pharmaceutical was developed and validated. This method include a sample cleanup by a solid phase extraction (SPE) using a polystyrene-divinyl benzene (PS-DVB) polymeric sorbent and high-performance liquid chromatography after precolumn fluorescent labeling of the histamine with o-phthaldialdehyde. The drug sample was loaded to the SPE cartridge after adjusting to pH 9.5. After successive washings of the cartridge with water and 30% aqueous methanol, histamine was then eluted with 100 mM sodium acetate (pH 9.5)-methanol (20:80, v/v). An aliquot from the eluate was labeled with o-phthaldialdehyde-mercaptoethanol (OPA-ME) for fluorescence detection at the excitation maximum of 340 nm and emission maximum of 450 nm. HPLC analysis was performed on a phenyl-hexyl column with an acetonitrile-phosphate buffer (pH 6.8; 50 microM) (35:65, v/v) as the mobile phase. The retention times of histamine and 3-methylhistamine (IS) were approximately 7.2 and 9.5 min, respectively. The quantitation range was between 0.01-0.2 mg/mL of histamine showing good linearity (r=0.9996). This analytical method would provide a potential mean for the strict control of histamine content in the pharmaceutical product.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge