Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Magnetic Resonance in Medicine 2012-Jun

Evaluation of multicontrast MRI including fat suppression and inversion recovery spin echo for identification of intra-plaque hemorrhage and lipid core in human carotid plaque using the mahalanobis distance measure.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Bernard C te Boekhorst
Ronald van 't Klooster
Sandra M Bovens
Kees W van de Kolk
Maarten J Cramer
Matthijs F van Oosterhout
Pieter A Doevendans
Rob J van der Geest
Gerard Pasterkamp
Cees J van Echteld

Kata kunci

Abstrak

Intra-plaque hemorrhage (IPH) and lipid core, characteristics of rupture prone carotid plaques, are often visualized in vivo with MRI using T1 weighted gradient and spin echo, respectively. Increasing magnetic field strength may help to identify IPH and lipid core better. As a proof of concept, automatic segmentation of plaque components was performed with the Mahalanobis distance (MD) measure derived from image contrast from multicontrast MR images including inversion recovery spin echo and T1 weighted gradient echo with fat suppression. After MRI of nine formaldehyde-fixated autopsy specimens, the MDs and Euclidean Distances between plaque component intensities were calculated for each MR weighting. The distances from the carotid bifurcation and the size and shape of calcification spots were used as landmarks for coregistration of MRI and histology. MD between collagen/cell-rich area and IPH was largest with inversion recovery spin echo (4.2/9.3, respectively), between collagen/cell-rich area/foam cells and lipid core with T1 weighted gradient echo with fat suppression (26.9/38.2/4.6, respectively). The accuracy of detection of IPH, cell-rich area, and collagen increased when the MD classifier was used compared with the Euclidean Distance classifier. The enhanced conspicuity of lipid core and IPH in human carotid artery plaque, using ex vivo T1 weighted gradient echo with fat suppression and inversion recovery spin echo MRI and MD classifiers, demands further in vivo evaluation in patients.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge