Acta Radiologica 2010-May

Flow properties of oral contrast medium formulations depend on the temperature.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Olle Ekberg
Mats Stading
Daniel Johansson
Margareta Bülow
Susanne Ekman
Karin Wendin

Kata kunci

Abstrak

BACKGROUND

During the therapeutic videofluoroscopic examination of swallowing, gradation of bolus volume, texture, and viscosity can be implemented to determine the optimal bolus characteristics in that particular patient. When a thickened liquid is given to a dysphagic patient it is served at room temperature. However, in these patients with a delayed oral and/or pharyngeal stage of swallow, the bolus is held for a long time in the oral cavity. The temperature of the thickened liquid thereby increases.

OBJECTIVE

To study the rheological exploration (variation of viscosity with temperature) of thickened food used for radiologic swallowing examinations in patients with oral and pharyngeal dysfunction, in particular in mixtures of barium sulfate suspensions and in iodine solutions.

METHODS

Deep-frozen mango purée was thawed at room temperature. It was then mixed with barium sulfate contrast medium to a density of 25% w/w. Resorce Thicken Up was mixed at room temperature at two concentrations: 4.3% w/w (4.5 g thickener + 100 g distilled water) and 6.0% w/w (4.5 g thickener + 70 g distilled water). The thickener consisted of modified corn starch. Resorce Thicken Up was also mixed at room temperature with two concentrations of an iodine contrast material, iohexol (Omnipaque, 350 mg I/ml). The two concentrations were: 4.3% w/w (4.5 g thickener + 100 g iohexol) and 6% w/w (6 g thickener + 100 g iohexol). Measurements were carried out from 20 degrees C to 37 degrees C using a Stresstech HR rheometer. The rheometer was equipped with a concentric cylinder measuring system (inner cylinder 15 mm).

RESULTS

The samples containing thickener in water as well as in iohexol showed a dependence on thickener concentration and temperature. The mango purée with barium sulfate displayed very small temperature dependence. The thickener solutions in iohexol had significantly higher viscosity compared with the other thickener solutions and the mango purée. The relative decrease shows that mango purée, the 6% thickener solution in water, and solutions with iohexol exhibited similar relative viscosity change at different temperatures.

CONCLUSIONS

Our conclusion is therefore that it is important always to make the solution with high precision. It is also of importance to observe how long the patient keeps the bolus in the mouth. This might vary and actually it may not be possible to influence this factor. When different types of thickeners are compared, it is important to take into account the temperature at which the thickener is observed.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge