Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Chemistry 2003-May

GC analysis of human breath with a series-coupled column ensemble and a multibed sorption trap.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Juan M Sanchez
Richard D Sacks

Kata kunci

Abstrak

The combination of a tandem column ensemble and an on-line microsorption trap is used for the analysis of organic compounds in human breath samples. The four-bed sorption trap uses a series of discreet sorption beds containing three grades of graphitized carbon and a carbon molecular sieve to quantitatively remove most organic compounds from 0.8-L breath samples. The trap is then heated to 300 degrees C in approximately 1.5 s and maintained at this temperature for 10 s. The resulting vapor plug width is in the range 0.7-1.3 s for the compounds found in the breath samples. The separation is performed with a 15-m-long, 0.25-mm-i.d. capillary using a 0.5-microm-thick film of nonpolar dimethyl polysiloxane coupled in series to a polar column, either trifluoropropylmethyl polysiloxane or poly(ethylene glycol). Both column combinations are successful in separating the early-eluting compounds acetone, isoprene, pentane, methyl alcohol, and ethyl alcohol, which are all common in breath samples. The poly(ethylene glycol) combination gave better separation but showed relatively fast deterioration for repeated analysis of wet samples. Breath samples were obtained under different conditions (smoker, nonsmoker, gum chewer), and 25 compounds were identified in the various samples. Many additional peaks are observed but not identified. Analytical curves (log-log) of peak area versus sample volume for test compounds are linear in the range 80-800 cm3. Detection limits (3sigma) for several volatile compounds in 800-cm3 samples are in the 1-5 ppb range.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge