Transplantation Proceedings 2010-Jun

Importance of organ preservation solution composition in reducing myocardial edema during machine perfusion for heart transplantation.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
M L Cobert
M Peltz
L M West
M E Jessen

Kata kunci

Abstrak

OBJECTIVE

Machine perfusion preservation has been used experimentally to extend the storage interval of donor hearts. We previously demonstrated that machine perfusion with glucose-supplemented Celsior preservation solution led to superior reperfusion function but resulted in increased myocardial edema compared with conventional static preservation. We hypothesized that other solutions that contain an oncotic agent, such as University of Wisconsin Machine Perfusion Solution (UWMPS), might reduce graft edema development while maintaining myocardial oxidative metabolism during long-term storage.

METHODS

Canine hearts were stored and perfused in a perfusion preservation device (LifeCradle; Organ Transport Systems) after cardioplegic arrest and donor cardiectomy. Hearts were perfused either with glucose-supplemented Celsior (which lacks an oncotic agent) or UWMPS (which contains hydroxyethyl starch) at 5 degrees C in the perfusion device over 10 hours. Oxygen consumption (MVO(2)), lactate accumulation, regional flow distribution, and myocardial water content were measured.

RESULTS

Hearts in both groups continued to extract oxygen over the entire perfusion interval. Lactate accumulation was minimal in both groups. Both solutions delivered perfusate evenly to all regions of myocardium. Heart weight increase (Celsior 31.3 +/- 4.3%, UWMPS -3.3 +/- 1.9%) and final myocardial water content (Celsior 80.2 +/- 1.3%, UWMPS 75.9 +/- 0.3%) were higher in the Celsior group (P < .005).

CONCLUSIONS

Donor hearts can be supported by a perfusion device over relatively extended storage intervals. These organs continue to undergo oxidative metabolism with little lactate accumulation. An oncotic agent appears to be important in limiting increases in myocardial water content. UWMPS appears to be superior for perfusion preservation of myocardium by reducing edema development during storage.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge