Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Breath Research 2018-Oct

MEMS sensor array-based electronic nose for breath analysis-a simulation study.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Anurag Gupta
T Sonamani Singh
R D S Yadava

Kata kunci

Abstrak

The paper presents a simulation study of breath analysis based on theoretical models of microelectromechanical structure (MEMS) cantilever sensor array. The purpose of this study is to suggest a methodology for the development of MEMS electronic nose (e-nose) for monitoring disease-specific volatiles in exhaled breath. Oxidative stress and diabetes are taken as case studies for the assessment of e-nose designs. The detection of ethane for general oxidative stress, isoprene for hypoxia, and acetone for diabetes are considered for targeted detection. A number of volatiles concurrently present in the exhaled breath are taken as interferents. The MEMS cantilevers are coated with volatile-selective polymers and are analyzed in both the static and dynamic modes. The sensor array is defined by polymer selections based on three data mining methods: principal component analysis (PCA), fuzzy c-means clustering (FCM), and fuzzy subtractive clustering (FSC). This utilizes vapor/polymer partition coefficients as a database. Analyses are carried out to find optimal combinations of the polymer selection method and cantilever sensing mode. Virtual breath analysis experiments are analyzed by PCA for target discrimination. It is found that no single combination works best in all conditions. The acetone (diabetes) detection is best in both sensing modes with the polymers selected by FSC; the isoprene (hypoxia) is detectable only in static sensing mode with polymers selected by FCM clustering; and the ethane (oxidative stress) detection is possible by all sensing modes and polymer selections, provided the breath samples are preconcentrated. This study suggests that it is difficult to realize a single general-purpose MEMS breath analyzer. The dedicated analyzers for specific disease indications can however be made with an optimal combination of sensing mode and polymer coatings.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge