Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Clinical Oral Investigations 2015-Mar

Particle size distributions determined by optical scanning and by sieving in the assessment of masticatory performance of complete denture wearers.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Lydia Eberhard
Sophie Schneider
Constantin Eiffler
Stefanie Kappel
Nikolaos Nikitas Giannakopoulos

Kata kunci

Abstrak

OBJECTIVE

Standard procedure for the measurement of masticatory performance is the fractionated sieving of fragmented test food, which is substantially time consuming. The aim of this study was to introduce a less laborious, comparable, and valid technique based on scanning.

METHODS

Fifty-six Optocal chewing samples were minced by wearers of complete dentures with 15 and 40 chewing strokes and analyzed by both a sieving and a scanning method. The sieving procedure was carried out using ten sieves (5.6, 4.0, 2.8, 2.0, 1.4, 1.0, 0.71, 0.5, 0.355, and 0.25 mm) and measuring the weight of the specific fractions. Scanning was performed with a flatbed scanner (Epson Expression1600Pro, Seiko Epson Corporation, Japan, 1,200 dpi). Scanned images underwent image analysis (ImageJ 1.42q, NIH, USA), which yielded descriptive parameters for each particle. Out of the 2D image, a volume was estimated for each particle. In order to receive a discrete particle size distribution, area-volume-conversion factors were determined. The cumulated weights yielded by either method were curve fitted with the Rosin-Rammler distribution (MATLAB, The MathWorks, Inc., Natick, USA) to determine the median particle size X 50.

RESULTS

The Rosin-Rammler distributions for sieving and scanning resembled each other and showed an excellent correlation in 15/40 chewing strokes (r = 0.995/r = 0.971, P < 0.01, Pearson's correlation coefficient). The median particle sizes varied between 4.77/3.04 and 5.36/5.28 mm (mean 5.07/4.67) for scanning and 4.69/2.39 and 5.23/5.43 mm (mean 5.03/4.57) for sieving. On average, scanning overestimated the X 50 values by 1/2.4 %. The scanning method took 10 min per sample in contrast to 50 min for sieving.

CONCLUSIONS

Optical scanning is a valid method comparable to sieving.

CONCLUSIONS

The described method is feasible and appropriate for the measurement of masticatory performance of denture wearers.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge