Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Pharmaceutical and Biomedical Analysis 2017-Apr

Quantification of EC-18, a synthetic monoacetyldiglyceride (1-palmitoyl-2-linoleoyl-3-acetyl-rac-glycerol), in rat and mouse plasma by liquid-chromatography/tandem mass spectrometry.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Heon-Min Ryu
Yoo-Seong Jeong
Chang-Soon Yim
Jong-Hwa Lee
Suk-Jae Chung

Kata kunci

Abstrak

EC-18 (i.e., 1-palmitoyl-2-linoleoyl-3-acetyl-rac-glycerol), an active ingredient in Rockpid®, has been reported to be useful in controlling various types of inflammations, particularly those caused by neutropenia. Although this product was originally approved as a functional food in Korea, it is currently in phase II clinical trials for use in managing the severe chemotherapy-induced neutropenia in patients with advanced breast cancer who are receiving intermediate febrile neutropenia risk chemotherapy. The objective of this study was to develop a rapid, sensitive method for the determination of EC-18 in rat and mouse plasma and to evaluate the applicability of the assay in pharmacokinetic studies. EC-18 was extracted with MeOH from rat and mouse plasma samples, and the extract directly introduced onto an LC-MS/MS system. The analyte and EC-18-d3, an internal standard, were analyzed by multiple reaction monitoring (MRM) at m/z transitions of 635.4→355.4 for EC-18 and 638.4→338.4 for the internal standard, respectively. The lower limit of quantification (LLOQ) was determined at 50ng/mL, with an acceptable linearity in the range from 50 to 10,000ng/mL (r>0.999) for both matrices. Validation parameters such as accuracy, precision, dilution, recovery, matrix effects and stability were found to be within the acceptance criteria of the assay validation guidelines, indicating that the assay is applicable for estimating EC-18 in concentrations in the range examined. EC-18 was readily determined in plasma samples for periods of up to 8h following an intravenous bolus injection of 1mg/kg in rats and at 5mg/kg in mice, respectively, and up to 24h following the oral administration of 2000mg/kg in mice. The findings indicate that the current analytical method is applicable for pharmacokinetic studies of EC-18 in small animals.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge