Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography A 2018-Oct

Self-assembling covalent organic framework functionalized poly (styrene-divinyl benzene-glycidylmethacrylate) composite for the rapid extraction of non-steroidal anti-inflammatory drugs in wastewater.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Weixia Li
Lin Huang
Dandan Guo
Yonggang Zhao
Yan Zhu

Kata kunci

Abstrak

The growing use of non-steroidal anti-inflammatory drugs (NSAIDs) has seriously affected human health and ecosystems, as a result, the World Health Organization (WHO) has regarded them as emerging contaminants. NSAID's polar nature and trace amount present in wastewater make their extraction and determination challenging in modern analytical science. Therefore, regarding the need, we herein report a rapid, sensitive and selective in-syringe solid-phase extraction (SPE) method coupled with ultrahigh performance liquid chromatography and UV detector for the determination of seven NSAIDs in environmental water samples. Specifically, the NSAIDs in water samples were directly extracted by using synthesized porous covalent organic framework functionalized poly (styrene-divinyl benzene-glycidylmethacrylate) composite (COF@PS-GMA) without further cleanup procedures. The adsorption of NSAIDs on COF@PS-GMA sorbent was investigated by using adsorption isotherms and kinetic studies. Various parameters, including amount of sorbent, pH of the samples, the volume of desorption solvent, and desorption time that were involved in in-syringe SPE were optimized. Under the optimized conditions, good linearity was observed at 0.005-5.0 μg mL-1 with method quantification limits (LOQs) estimated between 0.54-2.74 μg L-1. The recoveries of the seven NSAIDs at the level of 0.5, 5.0 and 20.0 μg L-1 were ranging from 84.3% to 99.6%.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge