Indonesian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Clinical Periodontology 2001-Jan

Substance loss caused by scaling with different sonic scaler inserts--an in vitro study.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
T Kocher
J Fanghänel
H Sawaf
R Litz

Kata kunci

Abstrak

OBJECTIVE

Depending on the phase of periodontal treatment, power-driven inserts with different power levels are necessary: during initial treatment and flap operations, it must be possible to remove calculus which firmly adheres to the root surface with great efficiency; in contrast, gentle root-surface instrumentation has a high priority during maintenance treatment. Recently, modified sonic scaler inserts have been introduced: diamond-coated inserts for open flap operations and slim probe-shaped sonic scaler inserts for deplaqueing during maintenance.

METHODS

We compared the substance removal by these inserts to that of a conventional insert. In a bench system which allows application force, stroke height, and width and frequency of instrumentation to be monitored and also permits assessment of the topography before and after instrumentation (yielding depth removal and removed volume), we instrumented aluminum rods in triplicate and bovine roots in a 5-fold repetition.

RESULTS

With high application forces (1.0 N), the diamond-coated inserts removed 30 to 50% more substance than the conventional one. Except for the slim inserts, there was a significant linear relationship between increasing force and removed volume. Probe-shaped inserts do not remove considerable substance even with increasing pressures.

CONCLUSIONS

Diamond-coated inserts remove tooth substance very effectively and must thus be handled with care: more pressure effects more removal. Probe-shaped inserts can be used without risk during maintenance visits.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge