European Spine Journal 2019-Oct

The most appropriate cervical vertebra for the measurement of occipitocervical inclination parameter: a validation study of C3, C4, and C5 levels using multi-positional magnetic resonance imaging.

Hanya pengguna terdaftar yang dapat menerjemahkan artikel
Masuk daftar
Tautan disimpan ke clipboard
Permsak Paholpak
Blake Formanek
Andrew Vega
Koji Tamai
Zorica Buser
Jeffrey Wang

Kata kunci

Abstrak

To evaluate which cervical level is the most appropriate level to measure occipitocervical inclination (OCI).Sixty-two patients with multi-positional MRI: 24 males and 38 females, who had cervical lordosis and had a disk degeneration grade of 3 or less were included. We measured patient's OCI at C3, C4, and C5, occipitocervical angle (OCA), occipitocervical distance (OCD), C2-7 angle, and cervical sagittal vertical axis (cSVA) in neutral, flexion, and extension position. The correlation between OCI and OCA, OCD, C2-7 angle, and cSVA on each cervical level in all three positions was tested using Pearson's correlation coefficient test. The difference between OCIs at each cervical level was tested by Wilcoxon signed-rank test. p value of less than 0.05 was set as a statistically significant level.C5 OCI showed statistically significant correlation with OCA, OCD, C2-7 angle, and cSVA in all three positions (p < 0.05, r = 0.214-0.525). C3 OCI in flexion (p = 0.393, r = 0.081) and C4 OCI in neutral and flexion (neutral p = 0.275, r 0.104; flexion p = 0.987, r = 0.002) did not show significant correlation with C2-7 angle. There was a statistically significant difference between C3, C4, and C5 OCIs in neutral and extension position (p < 0.05). At the same time, OCI showed statistically strong correlation between adjacent cervical levels (p < 0.001, r = 0.627-0.822).C5 cervical level is the most appropriate level for OCI measurement. OCI should be measured at the same cervical level at all time. C4 OCI can reliably substitute C5 OCI in case C5 which is invisible on radiographic image. These slides can be retrieved under Electronic Supplementary Material.

Bergabunglah dengan
halaman facebook kami

Database tanaman obat terlengkap yang didukung oleh sains

  • Bekerja dalam 55 bahasa
  • Pengobatan herbal didukung oleh sains
  • Pengenalan herbal melalui gambar
  • Peta GPS interaktif - beri tag herba di lokasi (segera hadir)
  • Baca publikasi ilmiah yang terkait dengan pencarian Anda
  • Cari tanaman obat berdasarkan efeknya
  • Atur minat Anda dan ikuti perkembangan berita, uji klinis, dan paten

Ketikkan gejala atau penyakit dan baca tentang jamu yang mungkin membantu, ketik jamu dan lihat penyakit dan gejala yang digunakan untuk melawannya.
* Semua informasi didasarkan pada penelitian ilmiah yang dipublikasikan

Google Play badgeApp Store badge