Icelandic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Adhesive Dentistry 2017-Nov

Effect of Mechanical Fatigue on the Bond Between Zirconia and Composite Cement.

Aðeins skráðir notendur geta þýtt greinar
Skráðu þig / skráðu þig
Krækjan er vistuð á klemmuspjaldið
Hugo A Vidotti
Ricardo M Carvalho
Paulo G Coelho
Willian F Zambuzzi
Gerson Bonfante
Accácio L do Valle
Estevam A Bonfante

Lykilorð

Útdráttur

To examine the effect of mechanical fatigue on the bond strength of resin composite cemented to silica-coated yttria-tetragonal zirconia polycrystal ceramic (Y-TZP).

Ten Y-TZP blocks were polished down to 600-grit silicon carbide paper. Specimens were silica coated by airborne-particle abrasion with 30-μm silica-modified Al2O3 particles. Blocks were cleaned in an ultrasonic bath, and a dental adhesive was applied and light cured for 20 s. Pre-cured composite blocks were luted to treated Y-TZP surfaces with a dual-curing resin cement. Half of the samples (n = 5) were subjected to mechanical fatigue before trimming (fatigue group) and the other half tested 24 h after bonding procedures (control group). Forty-five beam-shaped samples with an approximately 1 mm2 cross-sectional area were prepared for each group and tested in microtensile mode at 0.5 mm/min. Fractographic analysis was performed by optical and scanning electron microscopy. Only specimens that failed at the interface area were considered for statistical analysis. Weibull distribution (95% confidence bounds) was used to determine the characteristic strength (σ0 in MPa) and Weibull modulus (m) for each group. Probability of survival was calculated over the range of loads until specimens failed.

The control group showed σ0 = 45.91 MPa and m = 7.98, and the fatigue group σ0 = 43.94 MPa and m = 6.44 (p > 0.05). The probability of survival did not differ significantly between groups.

Fatigue did not affect the bond strength between silica-treated Y-TZP intaglio surfaces and composite cement under these experimental conditions.

Skráðu þig á
facebook síðu okkar

Heillasta gagnagrunnur lækningajurtanna sem studdur er af vísindum

  • Virkar á 55 tungumálum
  • Jurtalækningar studdir af vísindum
  • Jurtaviðurkenning eftir ímynd
  • Gagnvirkt GPS kort - merktu jurtir á staðsetningu (kemur fljótlega)
  • Lestu vísindarit sem tengjast leit þinni
  • Leitaðu að lækningajurtum eftir áhrifum þeirra
  • Skipuleggðu áhugamál þitt og vertu vakandi með fréttarannsóknum, klínískum rannsóknum og einkaleyfum

Sláðu inn einkenni eða sjúkdóm og lestu um jurtir sem gætu hjálpað, sláðu jurt og sjáðu sjúkdóma og einkenni sem hún er notuð við.
* Allar upplýsingar eru byggðar á birtum vísindarannsóknum

Google Play badgeApp Store badge