Analytical Chemistry 2015-Oct

Electrochemical aptasensor of cardiac troponin I for the early diagnosis of acute myocardial infarction.

Aðeins skráðir notendur geta þýtt greinar
Skráðu þig / skráðu þig
Krækjan er vistuð á klemmuspjaldið
Hunho Jo
Hyunwoo Gu
Weejeong Jeon
Hyungjun Youn
Jin Her
Seong-Kyeong Kim
Jeongbong Lee
Jae Ho Shin
Changill Ban

Lykilorð

Útdráttur

Cardiac troponin I (cTnI) is well-known as a promising biomarker for the early diagnosis of acute myocardial infarction (AMI). In this work, single-stranded DNA aptamers against cTnI were identified by the Systematic Evolution of Ligands by Exponential enrichment (SELEX) method. The aptamer candidates exhibited a high selectivity and sensitivity toward both cTnI and the cardiac Troponin complex. The binding affinities of each aptamer were evaluated based on their dissociation constants (Kd) by surface plasma resonance. The Tro4 aptamer that had the highest binding capacity to cTnI showed a very low Kd value (270 pM) compared with that of a cTnI antibody (20.8 nM). Furthermore, we designed a new electrochemical aptasensor based on square wave voltammetry using ferrocene-modified silica nanoparticles. The developed aptasensor demonstrated an excellent analytical performance for cTnI with a wide linear range of 1-10 000 pM in a buffer and a detection limit of 1.0 pM (24 pg/mL; S/N = 3), which was noticeably lower than the cutoff values (70-400 pg/mL). The specificity of the aptamers was also examined using nontarget proteins, demonstrating that the proposed sensor responded to only cTnI. In addition, cTnI was successfully detected in a human serum albumin solution. On the basis of the calibration curve that was constructed, the concentrations of cTnI in a solution supplemented with human serum were effectively measured. The calculated values correlated well with the actual concentrations of cTnI. It is anticipated that the highly sensitive and selective aptasensor for cTnI could be readily applicable for the accurate diagnosis of AMI.

Skráðu þig á
facebook síðu okkar

Heillasta gagnagrunnur lækningajurtanna sem studdur er af vísindum

  • Virkar á 55 tungumálum
  • Jurtalækningar studdir af vísindum
  • Jurtaviðurkenning eftir ímynd
  • Gagnvirkt GPS kort - merktu jurtir á staðsetningu (kemur fljótlega)
  • Lestu vísindarit sem tengjast leit þinni
  • Leitaðu að lækningajurtum eftir áhrifum þeirra
  • Skipuleggðu áhugamál þitt og vertu vakandi með fréttarannsóknum, klínískum rannsóknum og einkaleyfum

Sláðu inn einkenni eða sjúkdóm og lestu um jurtir sem gætu hjálpað, sláðu jurt og sjáðu sjúkdóma og einkenni sem hún er notuð við.
* Allar upplýsingar eru byggðar á birtum vísindarannsóknum

Google Play badgeApp Store badge