Icelandic
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Chemosphere 2013-Mar

Optimization of selective pressurized liquid extraction for extraction and in-cell clean-up of PCDD/Fs in soils and sediments.

Aðeins skráðir notendur geta þýtt greinar
Skráðu þig / skráðu þig
Krækjan er vistuð á klemmuspjaldið
Lan Do
Staffan Lundstedt
Peter Haglund

Lykilorð

Útdráttur

This paper describes the development of methods for selective extraction of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from soils and sediments, using pressurized liquid extraction with in-cell clean-up (SPLE). Two binary solvent mixtures, viz. dichloromethane/n-heptane (DCM/Hp), and diethylether/n-heptane (DEE/Hp), were evaluated. The SPLE extraction conditions were optimized using central composite face (CCF) design. Three factors were investigated: extraction temperature (60-160 °C), number of extraction cycles (1-3) and time per cycle (2-18 min). The results showed that DCM/Hp (1/1, v/v) and DEE/Hp (1/2, v/v) were the best extraction solvent compositions and that the extraction temperature was a critical factor that needed careful optimization to achieve high extraction efficiency without co-extraction of sulfuric acid. Under the optimal conditions, the SPLE methods provided results with good accuracy and precision. For the sandy soil certified reference material (CRM-529) the quantification results ended up in the range 82-110% as compared to the concentrations obtained by a reference method based on Soxhlet extraction and external column clean-up. Furthermore, for a clay soil (CRM-530) and a sediment reference material (WMS-01), the accuracy (trueness) of the TEQ values were +11% (DCM/Hp) and +8% (DEE/Hp) for CRM-530, +8% and -7% for WMS-01, respectively. The individual congener concentrations also agreed well with the certified values. These findings show that SPLE is a promising method for combined extraction and clean-up of PCDD/Fs in soil/sediment samples.

Skráðu þig á
facebook síðu okkar

Heillasta gagnagrunnur lækningajurtanna sem studdur er af vísindum

  • Virkar á 55 tungumálum
  • Jurtalækningar studdir af vísindum
  • Jurtaviðurkenning eftir ímynd
  • Gagnvirkt GPS kort - merktu jurtir á staðsetningu (kemur fljótlega)
  • Lestu vísindarit sem tengjast leit þinni
  • Leitaðu að lækningajurtum eftir áhrifum þeirra
  • Skipuleggðu áhugamál þitt og vertu vakandi með fréttarannsóknum, klínískum rannsóknum og einkaleyfum

Sláðu inn einkenni eða sjúkdóm og lestu um jurtir sem gætu hjálpað, sláðu jurt og sjáðu sjúkdóma og einkenni sem hún er notuð við.
* Allar upplýsingar eru byggðar á birtum vísindarannsóknum

Google Play badgeApp Store badge