Catheterization and Cardiovascular Interventions 2009-Nov

Balloon dilation of pulmonary valve stenosis in infants less than 3 kg: a 20-year experience.

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
Tevfik Karagoz
Kentaro Asoh
Edward Hickey
Rajiv Chaturvedi
Kyong-Jin Lee
David Nykanen
Lee Benson

Parole chiave

Astratto

OBJECTIVE

This study focused on the anatomical features and outcomes of percutaneous pulmonary valve balloon dilation (PVD) in newborns < or = 3 kg in weight.

BACKGROUND

Although PVD is the treatment of choice for isolated pulmonary valve stenosis, there are no studies detailing technical, anatomical, and outcome variables in the smallest of infants undergoing the procedure.

METHODS

A retrospective, consecutive review of all initial and follow-up echocardiograms, catheterization data, cineangiograms, and surgical records of all neonates less than 3 kg.

RESULTS

Fifty infants underwent 55 PVD's, median age 7 days and weight 2.7 kg. Congestive heart failure and/or cyanosis were present in 55%, 46% prostaglandin dependent, with 28% having a hypoplastic right ventricle. The pulmonary valve diameter median z-score was -2.6, (range -5.8 to 1.2, P < 0.0001 vs. normal). The procedure was accomplished in all but one child, using a balloon to annulus ratio of 1.3 (range 1.1 to 1.7). There was a reduction in both the peak right ventricular systolic pressure (P < 0.0001) and outflow gradient (P < 0.0001). There was no procedure related mortality, although six children died in long-term follow-up (14%). Reintervention was necessary in 15 infants within 8 months of the procedure. Pulmonary regurgitation, present in 36% after the procedure, showed a gradual increase over time while outflow gradients decreased and valve annular dimensions increased toward normal.

CONCLUSIONS

In infants < or = 3 kg, PVD is safe and effective. A large proportion remains free from surgery (76% at 10 years). Small valve annular dimensions show catch up growth with time.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca