Italian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
European journal of nuclear medicine 1999-Jun

Clinical validation of the avidin/indium-111 biotin approach for imaging infection/inflammation in orthopaedic patients.

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
E Lazzeri
M Manca
N Molea
S Marchetti
V Consoli
L Bodei
R Bianchi
M Chinol
G Paganelli
G Mariani

Parole chiave

Astratto

We report here the results of a validation study of the avidin/indium-111 biotin approach in patients with skeletal lesions. This study involved 54 patients with orthopaedic conditions: 20 patients with intermediate suspected osteomyelitis of the trunk, 19 patients with infection/inflammation of prosthetic joint replacements, and 15 patients with suspected osteomyelitis of appendicular bones. Avidin (3 mg) was injected as an i.v. bolus, followed 4 h later by 111In-biotin; imaging was acquired 30 min and 16-18 h after administration of 111In-biotin. Technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO)-labelled leucocyte scintigraphy was performed in 39/54 patients. The overall sensitivity of the avidin/111In-biotin scan was 97.7% (versus 88.9% for 99mTc-HMPAO leucocyte scintigraphy). While the diagnostic performance of avidin/111In-biotin scintigraphy was similar to that of 99mTc-HMPAO leucocyte scintigraphy in patients with prosthetic joint replacements or osteomyelitis of appendicular bones, the avidin/111In-biotin approach clearly performed better than 99mTc-HMPAO leucocyte scintigraphy in patients with suspected osteomyelitis of the trunk (100% sensitivity, specificity and accuracy versus 50% sensitivity, 100% specificity and 66.7% accuracy for 99mTc-HMPAO-leucocyte scintigraphy). These results demonstrate the feasibility of the avidin/111In-biotin approach for imaging sites of infection/inflammation in the clinical setting. Although no systematic advantages of avidin/111In-biotin scintigraphy were found versus 99mTc-HMPAO leucocyte scintigraphy, the newer scintigraphic method is more practicable and involves lower biological risk for the operators.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca
  • Cerca le erbe medicinali in base ai loro effetti
  • Organizza i tuoi interessi e tieniti aggiornato sulle notizie di ricerca, sperimentazioni cliniche e brevetti

Digita un sintomo o una malattia e leggi le erbe che potrebbero aiutare, digita un'erba e osserva le malattie ei sintomi contro cui è usata.
* Tutte le informazioni si basano su ricerche scientifiche pubblicate

Google Play badgeApp Store badge