Italian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Folia Biologica 1997

Drosophila melanogaster, Vicia faba and Arabidopsis thaliana short-term bioassays in genotoxicity evaluation of air and soil samples from sites surrounding two industrial factories in the Czech Republic.

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
K Chroust
P Kuglík
J Relichová
I Holoubek
J Cáslavský
R Veselská
M Rysková
J Benedík

Parole chiave

Astratto

The Somatic Mutation and Recombination Test (SMART) in wing cells of Drosophila melanogaster, the Vicia faba cytogenetic tests-Sister Chromatid Exchange (SCE) and Micronucleus Test (MN), and the Müller test for gametic mutations in Arabidopsis thaliana were used for genotoxicity testing of environmental samples of pollutants from the surroundings of LACHEMA chemical factory (Brno, Czech Republic) and DEZA factory in Valasské Mezirící (Moravia, Czech Republic). Tested soil and air samples were taken from the near vicinity of both factories. The surroundings of both sites are heavy loaded by exhalation of chemicals from the factories. Chemical analyses of the 16 Polycyclic Aromatic Hydrocarbons (PAHs) according to the United States Environmental Protection Agency (US EPA) list of priority pollutants and heavy metals were performed in both soil and air samples. The Drosophila wing spot test was positive in 70.6% of the tested samples, the Vicia sister chromatid exchange test in 62.5%, and the Arabidopsis Müller test in 58.9%. The micronucleus Vicia faba test was quite insensitive in tested environmental samples. The concordance between SMART and SCE was 62.5%, between SMART and Müller test 76.5%, and between Müller test and SCE 100%. Total concordance of these three tests was 79.7%. Müller test for gametic mutation in Arabidopsis thaliana and cytogenetic SCE test in Vicia faba seem to be quite sensitive and convenient plant bioassays for assessing the mutagenic potential of environmental agents, when compared to the SMART test in Drosophila melanogaster.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca
  • Cerca le erbe medicinali in base ai loro effetti
  • Organizza i tuoi interessi e tieniti aggiornato sulle notizie di ricerca, sperimentazioni cliniche e brevetti

Digita un sintomo o una malattia e leggi le erbe che potrebbero aiutare, digita un'erba e osserva le malattie ei sintomi contro cui è usata.
* Tutte le informazioni si basano su ricerche scientifiche pubblicate

Google Play badgeApp Store badge