European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology 2008-Jan

Profound hypoxaemia corrected by PFO closure device in carcinoid heart disease.

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
Philip M Mottram
David J McGaw
Ian T Meredith
Roger E Peverill
Richard W Harper

Parole chiave

Astratto

A 66-year-old man with known metastatic carcinoid tumor presented with increasing dyspnoea, right heart failure and marked hypoxaemia which did not correct with oxygen. Echocardiography demonstrated severe tricuspid regurgitation, moderate pulmonary regurgitation and marked right heart dilatation. The inter-atrial septum was aneurysmal, with a large patent foramen ovale (PFO) with continuous right to left shunting. Cardiac catheterization demonstrated oxygen saturations of 96% in the pulmonary veins and 74% in the left atrium with a significant right to left shunt. During percutaneous closure of the PFO, anaesthetic induction resulted in marked systemic hypotension and worsening hypoxia related to systemic vasodilatation and increased shunting. PFO flow was temporarily obstructed with a sizing balloon resulting in a rapid increase in arterial oxygen saturation from 60% to >90%, but marked systemic hypotension due to acute left ventricular preload reduction, requiring volume replacement and adrenaline. Following deployment of a PFO occluder device, prominent pulsatile splaying of the right and left discs was noted due to the severe tricuspid regurgitation, resulting in some residual inter-atrial shunting. Arterial oxygen saturation was 83%, increasing to 92% at day 4 post-procedure as tissue organization occurred within the device, and the patient reported improvement in dyspnoea.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca
  • Cerca le erbe medicinali in base ai loro effetti
  • Organizza i tuoi interessi e tieniti aggiornato sulle notizie di ricerca, sperimentazioni cliniche e brevetti

Digita un sintomo o una malattia e leggi le erbe che potrebbero aiutare, digita un'erba e osserva le malattie ei sintomi contro cui è usata.
* Tutte le informazioni si basano su ricerche scientifiche pubblicate

Google Play badgeApp Store badge