Journal of Oncology Pharmacy Practice 2006-Jun

The incidence of extravasation of vinca alkaloids supplied in syringes or mini-bags.

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
Peter J Gilbar
Christine V Carrington

Parole chiave

Astratto

OBJECTIVE

The aim of this retrospective study was to determine the incidence of vinca alkaloid extravasation following administration via syringes or mini-bags.

METHODS

An electronic survey was sent to pharmacy departments at hospitals throughout Australia. The survey was designed to collect data on the administration methods of vinca alkaloids (vincristine, vinblastine, vinorelbine) and the corresponding documented incidence of extravasation. The questionnaire requested the following information: how the drugs were prepared for administration (syringe or mini-bag); volume of each product; number of items supplied; and the number of cases of extravasation reported for each product.

RESULTS

Questionnaires were sent to 228 hospital pharmacy departments in Australia. Sixty-eight questionnaires were received (29.8%), including responses from most major cancer centres. Data represented a range of 3 to 120 months (mean: 38 months) of clinical experience. The reported incidence of vincristine extravasation from syringes was 0.03% (11/37 084) and 0.041% (3/7255) with mini-bags. One case of vinblastine extravasation was reported with syringes 0.013% (1/7913), none from mini-bags (0/1421). Vinorelbine data were difficult to interpret as cases may represent phlebitis rather than extravasation. The reported incidence from vinorelbine syringes was 0.029% (2/6914) and 0.146% (8/5475) with mini-bags. Excluding vinorelbine data, the reported vinca alkaloid extravasation episodes from syringes (0.027%) and mini-bags (0.035%) were found to be similar and infrequent.

CONCLUSIONS

The data suggest that vinca alkaloids can be given safely as low volume, short infusions via mini-bags. Policies and practices that ensure the same careful monitoring of infusional therapy as is recommended with administration by syringe may further reduce the incidence of untoward effects. Mini-bags should be used for the administration of vinca alkaloids and this practice will prevent the inadvertent intrathecal administration of vinca alkaloids via syringes.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca
  • Cerca le erbe medicinali in base ai loro effetti
  • Organizza i tuoi interessi e tieniti aggiornato sulle notizie di ricerca, sperimentazioni cliniche e brevetti

Digita un sintomo o una malattia e leggi le erbe che potrebbero aiutare, digita un'erba e osserva le malattie ei sintomi contro cui è usata.
* Tutte le informazioni si basano su ricerche scientifiche pubblicate

Google Play badgeApp Store badge