Italian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Ultraschall in der Medizin 2016-Oct

Ultrasound Strain Relaxation Time Ratio: A Quantitative Marker for the Assessment of Cortical Inflammation/Edema in Renal Allografts.

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
J Gao
K Hentel
J Kazam
R Min

Parole chiave

Astratto

Purpose: To evaluate the ability of ultrasound strain relaxation time ratio to assess cortical inflammation/edema in renal allografts. Materials and Methods: We prospectively assessed renal allograft cortical inflammation/edema in 16 renal transplants using ultrasound elasticity imaging and correlated the findings with kidney biopsy. Strain relaxation times in the renal cortex and reference soft tissue were produced by free-hand compression with the ultrasound transducer and estimated with 2 D speckle tracking. Compression was performed in 3-second compression-relaxation cycles (push for 1 second, constant pressure for 1 second, and release for 1 second). We propose a strain relaxation time ratio (time of cortical strain to return to zero/time of the reference strain return to zero) to assess the relationship of compression-induced time-dependent strain relaxation in the cortex and reference tissue. 16 patients were divided into a group with ≤ 25 % (n = 8) and a group with > 26 % (n = 8) cortical inflammation/edema based on the Banff score. A t-test was used to examine the difference in the strain relaxation time ratio between the two groups. The diagnostic accuracy, inter-rater reliability, and reproducibility of this technique in discriminating between the groups were tested. Results: The strain relaxation time ratio of cortex/reference tissue was significantly higher in patients with > 26 % than in patients with ≤ 25 % cortical inflammation/edema (1.15 ± 0.10 vs. 0.91 ± 0.08, P = 0.0002). The strain relaxation time ratio has high reliability (Pearson correlation coefficient, R² = 0.93), reproducibility (intraclass correlation coefficient = 0.98, P = 0.000), and accuracy (area under curve = 1) in determining > 26 % renal cortical inflammation/edema. Conclusion: The strain relaxation time ratio of cortex/reference tissue can be used as a quantitative marker for the assessment of cortical inflammation/edema in renal allografts.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca
  • Cerca le erbe medicinali in base ai loro effetti
  • Organizza i tuoi interessi e tieniti aggiornato sulle notizie di ricerca, sperimentazioni cliniche e brevetti

Digita un sintomo o una malattia e leggi le erbe che potrebbero aiutare, digita un'erba e osserva le malattie ei sintomi contro cui è usata.
* Tutte le informazioni si basano su ricerche scientifiche pubblicate

Google Play badgeApp Store badge