Italian
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Environmental Science and Pollution Research 2020-May

Development of Low-Cost Paper-Based Biosensor of Polyphenol Oxidase for Detection of Phenolic Contaminants in Water and Clinical Samples

Solo gli utenti registrati possono tradurre articoli
Entra registrati
Il collegamento viene salvato negli appunti
Rubia Noori
Mohammad Perwez
Jahirul Mazumder
Meryam Sardar

Parole chiave

Astratto

In the present work, polyphenol oxidase (PPO) enzyme was purified from potato peel using three-phase partitioning (TPP). In this method, ammonium sulfate and t-butanol were added to precipitate the protein/enzyme from the crude aqueous extract. The PPO enzyme precipitated as an interfacial layer between the upper organic solvent phase and lower aqueous phase. Different purification parameters such as crude extract to t-butanol ratio, ammonium sulfate concentration, temperature, and pH were optimized for TPP. About 69% PPO enzyme activity was recovered in a single step of TPP with 9.2-fold purification. The sodium dodecyl sulfate-polyacrylamide gel electrophoresis profile of partially purified PPO enzyme showed molecular weight in the range of about 30-40 kDa. The PPO enzyme was then investigated for the fabrication of a portable, cost-effective, and disposable colorimetric paper biosensor or colorimetric "test strips" for detection of phenolic contaminants. PPO and a chromophore reagent (3-methyl-2-benzothiazolinone hydrazine) generated a range of color in the presence of phenolic compounds (catechol, phenol, p-cresol, 4-methyl catechol) within 15 min, and limit of detection was found to be 0.5 μM. The biosensor worked in a broad range of pH from 3 to 11 and showed good storage stability at 25 °C and 4 °C for 30 days with no significant loss of activity. The biosensor was also applied on environmental water and urine sample to show reliability of biosensor.

Keywords: Biosensor; Catechol; Phenols; Pollutants; Polyphenol oxidase; Three-phase partitioning.

Unisciti alla nostra
pagina facebook

Il database di erbe medicinali più completo supportato dalla scienza

  • Funziona in 55 lingue
  • Cure a base di erbe sostenute dalla scienza
  • Riconoscimento delle erbe per immagine
  • Mappa GPS interattiva - tagga le erbe sul luogo (disponibile a breve)
  • Leggi le pubblicazioni scientifiche relative alla tua ricerca
  • Cerca le erbe medicinali in base ai loro effetti
  • Organizza i tuoi interessi e tieniti aggiornato sulle notizie di ricerca, sperimentazioni cliniche e brevetti

Digita un sintomo o una malattia e leggi le erbe che potrebbero aiutare, digita un'erba e osserva le malattie ei sintomi contro cui è usata.
* Tutte le informazioni si basano su ricerche scientifiche pubblicate

Google Play badgeApp Store badge