Anesthesiology 1990-Jan

Caffeine and halothane contracture testing in swine using the recommendations of the North American Malignant Hyperthermia Group.

רק משתמשים רשומים יכולים לתרגם מאמרים
התחבר הרשם
הקישור נשמר בלוח
G C Allen
J E Fletcher
F J Huggins
P A Conti
H Rosenberg

מילות מפתח

תַקצִיר

Caffeine and halothane contracture testing is widely used to detect malignant hyperthermia (MH) susceptibility. The accuracy and reliability of the 3% halothane test and the incremental caffeine test, as recommended by the North American MH Group, were assessed in 11 swine (five MHS, six control). Nine swine were tested twice, 4-6 weeks apart. Accuracy of the in vitro diagnosis was also assessed by in vivo anesthetic challenge. Of all muscle bundles from MH-susceptible swine, 65% reacted positively to 3% halothane and 70% to 2 mM caffeine. Only 35% had a positive caffeine-specific concentration, and 25% developed an increase in baseline tension greater than or equal to 7% at 2 mM caffeine. However, when only the most positive response to 3% halothane or to 2 mM caffeine was used (a minimum of three fresh muscle strips is recommended), these two tests were highly sensitive and specific. In control swine one of 30 muscle bundles reacted positively to 3% halothane. A positive caffeine-specific concentration developed in one of 25 control muscle bundles exposed to caffeine. The variability in the results of these tests mandated that at least three muscle bundles be used for each test. Nonviable muscle bundles could not be relied upon to provide accurate results. In this porcine model, MH susceptibility could be detected by performing the Caffeine Halothane Contracture Test (CHCT) according to the guidelines of the North American MH Group. However, only the 3% halothane test and the response to 2 mM caffeine produced adequate diagnostic results in this breed of swine.

הצטרפו לדף הפייסבוק שלנו

המאגר השלם ביותר של צמחי מרפא המגובה על ידי המדע

  • עובד ב 55 שפות
  • מרפא צמחי מרפא מגובה על ידי מדע
  • זיהוי עשבי תיבול על ידי דימוי
  • מפת GPS אינטראקטיבית - תייגו עשבי תיבול במיקום (בקרוב)
  • קרא פרסומים מדעיים הקשורים לחיפוש שלך
  • חפש עשבי מרפא על פי השפעותיהם
  • ארגן את תחומי העניין שלך והתעדכן במחקר החדשות, הניסויים הקליניים והפטנטים

הקלד סימפטום או מחלה וקרא על צמחי מרפא שעשויים לעזור, הקלד עשב וראה מחלות ותסמינים שהוא משמש נגד.
* כל המידע מבוסס על מחקר מדעי שפורסם

Google Play badgeApp Store badge