Hebrew
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Epilepsia

Evaluation of the mechanisms of antiepileptic drug-related chronic leukopenia.

רק משתמשים רשומים יכולים לתרגם מאמרים
התחבר הרשם
הקישור נשמר בלוח
C R O'Connor
P L Schraeder
A H Kurland
W H O'Connor

מילות מפתח

תַקצִיר

Antiepileptic drug (AED)-related chronic leukopenia [white blood cell (WBC) count < 4,000/microliters] is a dilemma, especially when the AED is effective in controlling seizures. We evaluated the possible mechanisms of leukopenia in 7 patients. Mean WBC count was 3,000/microliters with a mean of 42% polymorphonuclear leukocytes (PMN). The AEDs were carbamazepine (CBZ) alone in 1 patient or CBZ combined with phenytoin (PHT), primidone (PRM), phenobarbital (PB) and/or valproate (VPA) in 5 patients; one patient was receiving PHT only. Bone marrow (BM) aspirates and PMN antibody studies using chemiluminescence were normal. Two liver-spleen scans showed mild relative splenomegaly. After exercise, WBC count (n = 7) increased by 54% (SEM 12%), while the WBC counts in controls (n = 5) increased by 52 +/- 16%. Antinuclear antibodies (Hep-2) were absent in 6 patients and positive (1:160) in 1. PMN adhesion to nylon wool was decreased (54 +/- 10% in patients vs. 80 +/- 5% in controls: n = 13, p < 0.005). Our data, particularly the appropriate WBC response to the stress of exercise, and normal BM examinations suggest that continuation of AED therapy when leukopenia is stable and the percentage of PMN is normal is probably safe. Caution should be used if the absolute PMN count is consistently < 1,000/microliters. BM examinations need not be performed routinely for every patient with neutropenia due to AEDs, especially if the leukopenia fluctuates in the range of 2,000-4,000 cells/microliters.

הצטרפו לדף הפייסבוק שלנו

המאגר השלם ביותר של צמחי מרפא המגובה על ידי המדע

  • עובד ב 55 שפות
  • מרפא צמחי מרפא מגובה על ידי מדע
  • זיהוי עשבי תיבול על ידי דימוי
  • מפת GPS אינטראקטיבית - תייגו עשבי תיבול במיקום (בקרוב)
  • קרא פרסומים מדעיים הקשורים לחיפוש שלך
  • חפש עשבי מרפא על פי השפעותיהם
  • ארגן את תחומי העניין שלך והתעדכן במחקר החדשות, הניסויים הקליניים והפטנטים

הקלד סימפטום או מחלה וקרא על צמחי מרפא שעשויים לעזור, הקלד עשב וראה מחלות ותסמינים שהוא משמש נגד.
* כל המידע מבוסס על מחקר מדעי שפורסם

Google Play badgeApp Store badge