Hebrew
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Mass Spectrometry 2012-Jan

Rapid and robust confirmation and quantification of 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THC-COOH) in urine by column switching LC-MS-MS analysis.

רק משתמשים רשומים יכולים לתרגם מאמרים
התחבר הרשם
הקישור נשמר בלוח
Gabriele Zanchetti
Ivan Floris
Alberto Piccinotti
Silvia Tameni
Aldo Polettini

מילות מפתח

תַקצִיר

A method for the rapid and robust confirmation of 11-nor-∆9-tetrahydrocannabinol-9-carboxylic acid (THCA) in urine involving basic hydrolysis with NaOH and direct injection of the hydrolysate in a column-switching LC-MS-MS system was developed and validated. THCA-d3 was used as internal standard. Detection was performed in negative-ion mode by monitoring the transitions from the [M-CO(2) ]- ion m/z 299.2→245.2 and and m/z 299.2→191.1 that were found to provide a better signal-to-noise ratio than the transition from the pseudomolecular ion at m/z 343. The high sensitivity of detection enabled the injection of a small volume (10 µl) of the NaOH hydrolysate which, together with the applied column switching system, proved to confer ruggedness to the method and to avoid the deterioration of the instrumental apparatus despite the large amount of inorganic ions in the hydrolysate. The LLOQ was established at 5 ng/ml, and the LLOD was calculated as 0.2 ng/ml (S/N =3). The method was submitted to thorough validation including evaluation of the calibration range (5-500 ng/ml), accuracy and precision, matrix effects, overall process efficiency, autosampler stability, carryover and cross-talk, and 10-times reduction of sample volume (0.1 ml). Proof of applicability was obtained by direct comparison with the reference GC-MS method in use in the lab (the R(2) between the two methods was 0.9951).

הצטרפו לדף הפייסבוק שלנו

המאגר השלם ביותר של צמחי מרפא המגובה על ידי המדע

  • עובד ב 55 שפות
  • מרפא צמחי מרפא מגובה על ידי מדע
  • זיהוי עשבי תיבול על ידי דימוי
  • מפת GPS אינטראקטיבית - תייגו עשבי תיבול במיקום (בקרוב)
  • קרא פרסומים מדעיים הקשורים לחיפוש שלך
  • חפש עשבי מרפא על פי השפעותיהם
  • ארגן את תחומי העניין שלך והתעדכן במחקר החדשות, הניסויים הקליניים והפטנטים

הקלד סימפטום או מחלה וקרא על צמחי מרפא שעשויים לעזור, הקלד עשב וראה מחלות ותסמינים שהוא משמש נגד.
* כל המידע מבוסס על מחקר מדעי שפורסם

Google Play badgeApp Store badge