Hebrew
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2015-Jan

Rapid and sensitive analysis of nine fungicide residues in chrysanthemum by matrix extraction-vortex-assisted dispersive liquid-liquid microextraction.

רק משתמשים רשומים יכולים לתרגם מאמרים
התחבר הרשם
הקישור נשמר בלוח
Jiaying Xue
Xiaochu Chen
Wenqing Jiang
Fengmao Liu
Huichen Li

מילות מפתח

תַקצִיר

A simple sample pretreatment for simultaneous determination of nine fungicides (triadimefon, picoxystrobin, kresoxim-methyl, diniconazole, epoxiconazole, trifloxystrobin, triticonazole, difenoconazole, and azoxystrobin) in chrysanthemum was developed using matrix extraction-vortex-assisted dispersive liquid-liquid microextraction (ME-VADLLME) prior to gas chromatography with electron capture detection. The target fungicides were firstly extracted with acetonitrile and cleaned with the mixture of primary secondary amine and graphite carbon black. The VADLLME procedure was performed by using toluene with lower density than water as the extraction solvent and the acetonitrile extract as the dispersive solvent, respectively. After vortexing and centrifugation, the fine droplet of toluene was collected on the upper of the mixed toluene/acetonitrile/water system using a 0.1-mL pipettor. Under the optimum conditions, the relative recoveries ranged from 73.9 to 95.1% with relative standard deviations of 3.5-9.7% for all of the analytes. The limits of detection were in the range of (0.005-0.05)×10(-3) mg kg(-1). In the proposed method, the ME step provides more effective cleanup for the chrysanthemum matrix, and VADLLME introduces higher sensitivity with the remarkable enrichment factors up to 88-fold compared with the conventional QuEChERS or SPE. The good performance has demonstrated that ME-VADLLME has a strong potential for application in the multi-residue analysis of complex matrices.

הצטרפו לדף הפייסבוק שלנו

המאגר השלם ביותר של צמחי מרפא המגובה על ידי המדע

  • עובד ב 55 שפות
  • מרפא צמחי מרפא מגובה על ידי מדע
  • זיהוי עשבי תיבול על ידי דימוי
  • מפת GPS אינטראקטיבית - תייגו עשבי תיבול במיקום (בקרוב)
  • קרא פרסומים מדעיים הקשורים לחיפוש שלך
  • חפש עשבי מרפא על פי השפעותיהם
  • ארגן את תחומי העניין שלך והתעדכן במחקר החדשות, הניסויים הקליניים והפטנטים

הקלד סימפטום או מחלה וקרא על צמחי מרפא שעשויים לעזור, הקלד עשב וראה מחלות ותסמינים שהוא משמש נגד.
* כל המידע מבוסס על מחקר מדעי שפורסם

Google Play badgeApp Store badge