Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2011-Jan

A sensitive LC-MS/MS method for the quantitative analysis of the Echinacea purpurea constituent undeca-2-ene-8,10-diynoic acid isobutylamide in human plasma.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Andrew K L Goey
Rolf W Sparidans
Irma Meijerman
Hilde Rosing
Jan H M Schellens
Jos H Beijnen

キーワード

概要

Echinacea purpurea is one of the most popular herbal medicines and is known for its immunostimulatory effects. Alkylamides are the main lipophilic components of E. purpurea that contribute to its pharmacological actions. For quantification in human plasma of one of these alkylamides, undeca-2-ene-8,10-diynoic acid isobutylamide, a sensitive LC-MS/MS assay has been developed and validated. Plasma samples were pretreated using liquid-liquid extraction with a mixture of diethyl ether and n-hexane (50:50, v/v). Dried extracts were reconstituted in 50 μL of acetonitrile-water (50:50, v/v) after which 15 μL of sample was injected into the HPLC system. HPLC was performed using a Polaris 3 C18-A column (50 mm×2 mm ID) and isocratic elution with acetonitrile-water (50:50, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. Subsequently, electrospray ionization in the positive ion mode followed by tandem mass spectrometry was performed for detection. The total run time was 3 min. The assay was validated over a concentration range from 0.05 to 50 ng/mL for undeca-2-ene-8,10-diynoic acid isobutylamide, with 0.05 ng/mL being the lower limit of quantification using 1.0 mL plasma samples. Inter-assay inaccuracy (±12.7%), within-day and between-day precisions (CV≤8.23%) were acceptable. Further, undeca-2-ene-8,10-diynoic acid isobutylamide was found to be chemically stable under relevant conditions. Finally, the applicability of this assay has been successfully demonstrated in a pharmacokinetic experiment in which a human volunteer ingested a commercial extract of E. purpurea.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge