Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Chemistry 2007-Mar

Comparison of atmospheric pressure photoionization and atmospheric pressure chemical ionization for normal-phase LC/MS chiral analysis of pharmaceuticals.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Sheng-Suan Cai
Karl A Hanold
Jack A Syage

キーワード

概要

In this work, we compared APPI and APCI for normal-phase LC/MS chiral analysis of five pharmaceuticals. Performance was compared both by FIA and by on-column analysis using a ChiralPak AD-H column under optimized conditions. By comparison, APPI generated more reproducible signals and was less susceptible to ion suppression than APCI. APPI generated higher peak area and lower baseline noise, and therefore much higher S/N ratios. APPI sensitivity (i.e., S/N ratio) was approximately 2-130 times higher than APCI by FIA and was approximately 2.6-530 times higher than APCI by on-column analysis depending on specific compounds. The better APPI sensitivity as compared to APCI was more dramatic by on-column analysis than by FIA. APCI sensitivity was degraded by ion suppression caused by LC column bleeding components and by elevated APCI baseline noise relative to APPI. On-column APPI LODs (at S/N = 3) were 83, 16, 17, 95, and 7 pg for enantiomer #1, and 104, 23, 19, 122, and 17 pg for enantiomer #2 for benzoin, naringenin, mianserin, mephenesin, and diperodon, respectively, on a Waters ZQ. APPI offers no concern of explosion hazard relative to APCI corona needle discharge or ESI high voltage discharge when flammable solvents (e.g., hexane) are used as mobile phases. Whether APPI dopants are required depends on the IP(s) of mobile-phase solvent(s) and solvent complexes, and photon energies of VUV lamps. Dopant was not necessary for hexane-based mobile phases due to their self-doping effects. Dopants did enhance Kr lamp APPI sensitivity when MeOH was used as the mobile phase. However, dopants became unnecessary for the MeOH mobile phase when the Ar lamp was used.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge