Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Talanta 2008-Sep

Development and validation of reversed phase liquid chromatographic method utilizing ultraviolet detection for quantification of irinotecan (CPT-11) and its active metabolite, SN-38, in rat plasma and bile samples: application to pharmacokinetic studies.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Tripta Bansal
Anshumali Awasthi
Manu Jaggi
Roop K Khar
Sushama Talegaonkar

キーワード

概要

A new, simple, sensitive and specific reversed-phase high performance liquid chromatographic (HPLC) method using ultraviolet detection was developed and validated for the analysis of CPT-11 (lambda(max)=254 nm, 365 nm) and its major active metabolite, SN-38 (lambda(max)=380 nm) in rat plasma and bile. The sample pre-treatment from plasma involved a single protein precipitation step with cold acetonitrile. In case of bile, liquid-liquid extraction with dichloromethane: tert-butyl methyl ether (3:7) was carried out. Topotecan, a structurally related camptothecin, was used as an internal standard. An aliquot of 50 microL was injected onto a C-18 column. The chromatographic separation was achieved by gradient elution consisting of acetonitrile and water (pH 3.0 adjusted with 20% o-phosphoric acid) at a flow rate of 1.0 ml/min. Total run time for each sample was 30 min. All the analytes viz. topotecan, CPT-11, SN-38 were well separated with retention times of 11.4, 13.4 and 15.5 min, respectively. Method was found to be selective, linear (R(2) approximately 0.999), accurate (recovery+/-15%) and precise (<5% C.V.) in the selected concentration ranges for both the analytes. The quantification limit for CPT-11 was 40 ngml(-1) and for SN-38 was 25 ngml(-1). The percent extraction efficiency was approximately 97% for CPT-11 and SN-38 from plasma while extraction recovery of CPT-11 and SN-38 from bile was approximately 70% and approximately 60%, respectively. The method was successfully used to determine plasma and biliary excretion time profiles of CPT-11 and SN-38, following oral and intravenous CPT-11 administration in rats. In the present study, irinotecan showed an absolute bioavailability of 30% as calculated from the pharmacokinetic data.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge