Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
JAMA Pediatrics 2016-Mar

Intravenous Fluid Bolus Prior to Neonatal and Infant Lumbar Puncture: A Sonographic Assessment of the Subarachnoid Space After Intravenous Fluid Administration.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Jessica Rankin
Vincent J Wang
Fariba Goodarzian
Hollie A Lai

キーワード

概要

OBJECTIVE

Neonatal and infant lumbar puncture is a commonly performed procedure in emergency departments, yet traumatic and unsuccessful lumbar punctures occur 30% to 50% of the time. Dehydration may be a risk factor for unsuccessful lumbar punctures, but to our knowledge, no studies have investigated the use of intravenous (IV) fluid bolus prior to lumbar puncture.

OBJECTIVE

To investigate the association of IV fluid bolus administration with the sonographic measure of the neonatal and infant lumbar subarachnoid space. We hypothesized that IV fluids would increase subarachnoid space size.

METHODS

Prospective observational study conducted from August 2012 to April 2015.The study took place at the emergency department of the Children's Hospital Los Angeles, an urban pediatric emergency department with an annual census of 76,000 visits.A convenience sample of patients aged 0 to 3 months were enrolled if they had a clinical presentation consistent with pyloric stenosis. This population was used as a proxy because they are similar in age to patients undergoing lumbar puncture for evaluation of neonatal fever and are routinely given IV fluids for dehydration.

METHODS

Patients with a sonographic diagnosis of pyloric stenosis underwent additional ultrasonography evaluation to determine the size of the subarachnoid space before and after IV fluids.

METHODS

Primary outcomes included the difference in the size of the subarachnoid space in millimeters squared before and 1 hour after administration of an IV fluid bolus in the emergency department. Interobserver consistency for the subarachnoid space measurement between attending radiologists was measured using intraclass correlation coefficient. The Wilcoxon signed-rank test was used to examine changes in subarachnoid space measurements (millimeters squared).

RESULTS

The study sample consisted of 40 patients with a mean (SD) age of 37 (11.3) days (range, 15-71 days). The mean (SD) size of the subarachnoid space before and 1 hour after IV fluid bolus was 37.8 (11.1) mm(2) and 36.9 (11.2) mm(2) respectively (P = .42). The intraclass correlation coefficient ranged from 0.96 to 0.99 (95% CI, 0.90-0.99).

CONCLUSIONS

Intravenous fluid boluses were not associated with a significant increase in the sonographic measure of the neonatal and infant subarachnoid space.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge