Kidney International 1980-Oct

Leukopenia, hypoxia, and complement function with different hemodialysis membranes.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
A I Jacob
G Gavellas
R Zarco
G Perez
J J Bourgoignie

キーワード

概要

Complement activation during exposure of plasma to cuprophan has been postulated to cause leukopenia and hypoxia in hemodialysis patients. To determine if hypoxia is related to leukopenia and if complement activation leads to a depletion of functional complement components, we dialyzed four patients three times sequentially against each of four types of membranes: cuprophan, regenerated cellulose, cellulose acetate, and polyacrilonitrile. Within 20 min there was a marked leukopenia with cuprophan from 5541 +/- 376 to 1216 +/- 94 (P less than 0.001) and with regenerated cellulose from 5541 +/- 411 to 1533 +/- 203 (P less than 0.001). With cellulose acetate, the change from 5558 +/- 400 to 3783 +/- 341 (P less than 0.001) was less dramatic, and with polyacrilonitrile the fall from 5591 +/- 381 to 464 +/- 401 (P less than 0.02) was minimal. After 2 and 4 hours of dialysis, a rebound leukocytosis was seen with cuprophan, regenerated cellulose, and cellulose acetate, but not with polyacrilonitrile. Transient thrombocytopenia occurred with cuprophan and regenerated cellulose. In spite of the variable degree of leukopenia, all membranes induced a similar and significant hypoxia, which was progressive throughout dialysis, even during the rebound leukocytosis. After 4 hours, the mean PO2 ranged from 91 to 93 mm Hg with all membranes. Functional hemolytic titers of whole complement, C3, C5, and C4 were normal prior to hemodialysis and failed to decrease after 4 hours with any membrane. It is concluded that hemodialysis leukopenia is membrane-dependent and is not the cause of hypoxia. In addition, hemodialysis complement activation does not lead to functional complement depletion and is of no clinical significance.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge