Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Yonsei Medical Journal 1999-Feb

The validity of random urine specimen albumin measurement as a screening test for diabetic nephropathy.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
C W Ahn
Y D Song
J H Kim
S K Lim
K H Choi
K R Kim
H C Lee
K B Huh

キーワード

概要

To assess the validity of urine albumin concentration (UAC) and the urine albumin:creatine ratio (UACR) in a random urine specimen (RUS) for screening diabetic nephropathy in Korea, a total of 105 ambulatory diabetes mellitus patients (male:female, 52:53), ages 40-75 years (median 59 years) collected 105 RUSs after completing a timed 24 hour urine collection. Albumin was measured by immunonephelometry. According to the timed urinary albumin excretion rate (UAER) measured in the 24 hour collection (criterion standard), samples were classified normoalbuminuric (UAER < 20 micrograms/min; n = 50), microalbuminuric (UAER 20-200 micrograms/min; n = 30), and macroalbuminuric (UAER > 200 micrograms/min; n = 25). The receiver operating characteristics (ROC) curve of UAC and UACR in a RUS for screening of microalbuminuria (normo- and microalbuminuric samples; n = 80) and macroalbuminuria (micro- and macroalbuminuric samples; n = 55) were plotted. Pearson's coefficients of correlation of 24 hour UAER vs. UAC and UACR were 0.81 and 0.75, respectively (P < 0.001). The point of intersection with a 100%-to-100% diagonal for microalbuminuria were as follows: 31.0 mg/l for UAC and 32.5 mg/g for UACR; for macroalbuminuria 181 mg/l for UAC and 287.3 mg/g for UACR. The sensitivity and specificity of the cut-off points for microalbuminuria were 77% and 82% for UAC and 77% and 92% for UACR. The sensitivity and specificity of the cut-off points for macroalbuminuria were 84% and 90% for UAC and 88% and 90% for UACR. In present study, no difference was observed when comparing the performance of UAC and UACR based on a statistical comparison by McNemar test. The repeated measurements of UAC and UACR in the same individual were statistically similar and were correlated with each other. Based on these results, albumin measurements (UAC and UACR) in a RUS were considered as a valid test for screening diabetic nephropathy.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge