Japanese
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Investigative Ophthalmology and Visual Science 2004-Dec

Tissue adhesives for a sutureless fadenoperation: an experimental study in a rabbit model.

登録ユーザーのみが記事を翻訳できます
ログインサインアップ
リンクがクリップボードに保存されます
Edward Tonelli
Henderson Celestino de Almeida
Eduardo Alves Bambirra

キーワード

概要

OBJECTIVE

To use tissue adhesives for a sutureless Fadenoperation to eliminate perioperative risks related to the sutures.

METHODS

In an in vivo procedure, 120 superior recti muscles in New Zealand White rabbits were subjected to the posterior fixation procedure, at a distance of 6 mm from the insertion point of the muscle. They were divided into four groups of 30 muscles, according to the material used to perform a myopexy: group 1 (control): nonabsorbable 5-0 polyester sutures; group 2: n-butyl-2-cyanoacrylate adhesive; group 3: fibrin glue; group 4: gelatin-resorcin-formaldehyde-glutaraldehyde (GRFG) adhesive. The animals were examined at 1, 7, 14, and 21 days after surgery. Afterward, they were killed, and their eyes were enucleated to measure the distance between the myopexy and the anatomic insertion point and to assure the strength of the bond with a dynamometer. Finally, a histologic examination was performed.

RESULTS

Almost all eyes were clear after the third week, although group 4 presented the most intense inflammatory reaction. In histologic examination, groups 1 and 2 showed a chronic inflammatory reaction of the foreign-body type, with similar intensity. Fibrin glue induced minimal inflammation, but GRFG adhesive produced a pronounced reaction. Concerning the distance of the myopexy, groups 1 and 2 presented measures close to the expected distance of 6 mm, whereas groups 3 and 4 showed a greater variability. All groups performed well in the strength test, with no statistically significant differences among them.

CONCLUSIONS

n-Butyl-2-cyanoacrylate adhesive performed best in the sutureless Fadenoperation, characterized by precision in the expected distance of myopexy, sufficient resistance to separation, and acceptable inflammatory reaction.

Facebookページに参加する

科学に裏打ちされた最も完全な薬草データベース

  • 55の言語で動作します
  • 科学に裏打ちされたハーブ療法
  • 画像によるハーブの認識
  • インタラクティブGPSマップ-場所にハーブをタグ付け(近日公開)
  • 検索に関連する科学出版物を読む
  • それらの効果によって薬草を検索する
  • あなたの興味を整理し、ニュース研究、臨床試験、特許について最新情報を入手してください

症状や病気を入力し、役立つ可能性のあるハーブについて読み、ハーブを入力して、それが使用されている病気や症状を確認します。
*すべての情報は公開された科学的研究に基づいています

Google Play badgeApp Store badge