Korean
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences 2017-May

An on-line HPLC system for detection of antioxidant compounds in some plant extracts by comparing three different methods.

등록 된 사용자 만 기사를 번역 할 수 있습니다.
로그인 / 가입
링크가 클립 보드에 저장됩니다.
Nesibe Arslan Burnaz
Murat Küçük
Zeynep Akar

키워드

요약

Echinacea (Echinacea purpurea), green tea (Camellia sinensis) and yaylacayi (Thymus praecox OPIZ subsp. grossheimii (Ronniger) Jalas) are herbs used in traditional medicine because of their beneficial health effects. A high performance liquid chromatography (HPLC) post-column method was developed by coupling HPLC with on-line antioxidant assays using diode array (DAD) and ultraviolet (UV) detectors. Thus antioxidant compounds and fifteen phenolic standards were detected in echinacea, green tea and yaylacayi methanol extracts simultaneously. Later on, the developed on-line HPLC coupled system was used to compare three different antioxidant methods, ABTS [2,2'-Azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid)], DPPH (2,2-diphenyl-1-picrylhydrazyl and FRAP (Ferric reducing antioxidant power). Eight compounds with antioxidant activity were identified as gallic acid, protocatechuic aldehyde, p-OH benzoic acid, chlorogenic acid, caffeic acid, vanillin, ferulic acid, and rosmarinic acid. For validation purposes, LOD (limit of detection) (0.36-14.68μg/mL) and LOQ (limit of quantification) (1.35-48.92μg/mL) values were calculated for six standards. The results showed that while the post-column ABTS and FRAP assays were repeatable, sensitive and supportive of each other, the post-column DPPH assay did not provide reliable results. Also due to the base-line noise and drifts in post-column DPPH assay, identification and quantitation of analytes could not be done accurately.

페이스 북
페이지에 가입하세요

과학이 뒷받침하는 가장 완벽한 약초 데이터베이스

  • 55 개 언어로 작동
  • 과학이 뒷받침하는 약초 치료제
  • 이미지로 허브 인식
  • 인터랙티브 GPS지도-위치에 허브 태그 지정 (출시 예정)
  • 검색과 관련된 과학 출판물 읽기
  • 효과로 약초 검색
  • 관심사를 정리하고 뉴스 연구, 임상 실험 및 특허를 통해 최신 정보를 확인하세요.

증상이나 질병을 입력하고 도움이 될 수있는 약초에 대해 읽고 약초를 입력하고 사용되는 질병과 증상을 확인합니다.
* 모든 정보는 발표 된 과학 연구를 기반으로합니다.

Google Play badgeApp Store badge