Korean
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Chemistry 2009-Nov

Design of molecular beacons as signaling probes for adenosine triphosphate detection in cancer cells based on chemiluminescence resonance energy transfer.

등록 된 사용자 만 기사를 번역 할 수 있습니다.
로그인 / 가입
링크가 클립 보드에 저장됩니다.
Shusheng Zhang
Yameng Yan
Sai Bi

키워드

요약

In the present study, binary and triplex DNA molecular beacons, as signaling probes based on a luminol-H(2)O(2)-horseradish peroxidase (HRP)-fluorescein chemiluminescence resonance energy transfer (CRET) system and structure-switching aptamers for highly sensitive detection of small molecules, are developed using adenosine triphosphate (ATP) as a model analyte to demonstrate the generality of the strategy. This CRET process occurs from donor luminol to acceptor fluorescein, which is oxidized by H(2)O(2) and catalyzed by HRP. DNA aptamer for ATP is first attached on the surface of magnetic nanoparticles (MNPs). The cDNA linker has an extension that hybridizes with two other DNAs (LumAuNP-DNA and F-DNA) or three other DNAs (HRP-DNA, LumAuNP-DNA, and F-DNA) to fabricate CRET-BMBP-MNP or CRET-TMBP-MNP conjugates that provide the CRET signals. Thus, in the absence of ATP, when the MNPs are removed from the solution, they also take with them the linker DNA and the CRET signal probes, and no CRET signal can be detected. However, when ATP is introduced, a competition for the ATP aptamer between ATP and the cDNA linker occurs. As a result, CRET-BMBP and CRET-TMBP are forced to dissociate from the MNP surface based on the structure switching of the aptamer. The CRET signals are proportional to the concentration of ATP. In order to accelerate the rate of the aptamer structure-switching process, an invader DNA is introduced into the proposed strategy. The present CRET system provides a low detection limit of 1.1 x 10(-7) and 3.2 x 10(-7) M for ATP detection by BMBP and TMBP, respectively, which also exhibits a good selectivity for ATP detection. Sample assays of ATP in K562 leukemia cells and 4T1 breast cancer cells confirm the reliability and practicality of the protocol, which reveal a good prospect of this platform for biological sample analysis.

페이스 북
페이지에 가입하세요

과학이 뒷받침하는 가장 완벽한 약초 데이터베이스

  • 55 개 언어로 작동
  • 과학이 뒷받침하는 약초 치료제
  • 이미지로 허브 인식
  • 인터랙티브 GPS지도-위치에 허브 태그 지정 (출시 예정)
  • 검색과 관련된 과학 출판물 읽기
  • 효과로 약초 검색
  • 관심사를 정리하고 뉴스 연구, 임상 실험 및 특허를 통해 최신 정보를 확인하세요.

증상이나 질병을 입력하고 도움이 될 수있는 약초에 대해 읽고 약초를 입력하고 사용되는 질병과 증상을 확인합니다.
* 모든 정보는 발표 된 과학 연구를 기반으로합니다.

Google Play badgeApp Store badge