Feasibility of myocardial perfusion imaging studies in morbidly obese patients with a cadmium-zinc-telluride cardiac camera.

등록 된 사용자 만 기사를 번역 할 수 있습니다.
로그인 / 가입
링크가 클립 보드에 저장됩니다.
Anna Budzyńska
Sebastian Osiecki
Andrzej Mazurek
Stanisław Piszczek
Mirosław Dziuk

키워드

요약

A novel cardiac SPECT camera with cadmium-zinc-telluride (CZT) based technology has a fixed array of semiconductor detectors paired with pinhole collimators focused on the heart. Image acquisition in obese patients can be challenging because of much smaller detector field of view compared to conventional gamma cameras. The aim of this study was to evaluate the impact on high body mass on the feasibility of CZT myocardial perfusion imaging (MPI). The additional aim was to investigate the mechanism of the banana-shaped/obesity artifact, as referred to in literature, and to attempt at simulating it on a phantom study.Study group consisted of 43 patients with morbid obesity (BMI ≥ 40 kg/m2). All these patients underwent myocardial perfusion imaging on both CZT cardiac camera and general purpose SPECT/CT gamma camera. Control group consisted of all patients who underwent myocardial perfusion imaging on CZT camera throughout one calendar year and whose BMI was lower than 40 kg/m2. In this group, all repeated studies were re-analyzed for estimating the frequency of heart mispositioning in the camera field of view. The number of studies performed was 1180. A static cardiac phantom was used to simulate a banana-shaped artifact. A series of phantom acquisitions during which the phantom position was altered in the camera field of view was performed.In control group, 3.7% of all cardiac scintigrams required repetition, 18.9% of which were repeated due to wrong heart positioning; median BMI in this group of patients was 36.0. A banana-shaped artifact was observed in one female patient with BMI 36.0. In morbid obesity group, 32.6% of the studies were non-diagnostic with "truncation effect" on Scan Quality Control (QC). Median BMI in patients with diagnostic scans was 42.0, while in patients with not acceptable quality control test it was 45.0 (p < 0.05). Banana-shaped artifacts were observed in 5 non-diagnostic studies. In a phantom study an artifact of banana shape was obtained when gantry was distant from the phantom and target was on the edge of the camera field of view and was slightly truncated.Problem with heart mispositioning during imaging on the CZT camera affects less than 1% of all performed studies. Morbid obesity is not a contraindication to perform myocardia.

페이스 북
페이지에 가입하세요

과학이 뒷받침하는 가장 완벽한 약초 데이터베이스

  • 55 개 언어로 작동
  • 과학이 뒷받침하는 약초 치료제
  • 이미지로 허브 인식
  • 인터랙티브 GPS지도-위치에 허브 태그 지정 (출시 예정)
  • 검색과 관련된 과학 출판물 읽기
  • 효과로 약초 검색
  • 관심사를 정리하고 뉴스 연구, 임상 실험 및 특허를 통해 최신 정보를 확인하세요.

증상이나 질병을 입력하고 도움이 될 수있는 약초에 대해 읽고 약초를 입력하고 사용되는 질병과 증상을 확인합니다.
* 모든 정보는 발표 된 과학 연구를 기반으로합니다.

Google Play badgeApp Store badge