Korean
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Transplantation Proceedings 2010-Jun

Importance of organ preservation solution composition in reducing myocardial edema during machine perfusion for heart transplantation.

등록 된 사용자 만 기사를 번역 할 수 있습니다.
로그인 / 가입
링크가 클립 보드에 저장됩니다.
M L Cobert
M Peltz
L M West
M E Jessen

키워드

요약

OBJECTIVE

Machine perfusion preservation has been used experimentally to extend the storage interval of donor hearts. We previously demonstrated that machine perfusion with glucose-supplemented Celsior preservation solution led to superior reperfusion function but resulted in increased myocardial edema compared with conventional static preservation. We hypothesized that other solutions that contain an oncotic agent, such as University of Wisconsin Machine Perfusion Solution (UWMPS), might reduce graft edema development while maintaining myocardial oxidative metabolism during long-term storage.

METHODS

Canine hearts were stored and perfused in a perfusion preservation device (LifeCradle; Organ Transport Systems) after cardioplegic arrest and donor cardiectomy. Hearts were perfused either with glucose-supplemented Celsior (which lacks an oncotic agent) or UWMPS (which contains hydroxyethyl starch) at 5 degrees C in the perfusion device over 10 hours. Oxygen consumption (MVO(2)), lactate accumulation, regional flow distribution, and myocardial water content were measured.

RESULTS

Hearts in both groups continued to extract oxygen over the entire perfusion interval. Lactate accumulation was minimal in both groups. Both solutions delivered perfusate evenly to all regions of myocardium. Heart weight increase (Celsior 31.3 +/- 4.3%, UWMPS -3.3 +/- 1.9%) and final myocardial water content (Celsior 80.2 +/- 1.3%, UWMPS 75.9 +/- 0.3%) were higher in the Celsior group (P < .005).

CONCLUSIONS

Donor hearts can be supported by a perfusion device over relatively extended storage intervals. These organs continue to undergo oxidative metabolism with little lactate accumulation. An oncotic agent appears to be important in limiting increases in myocardial water content. UWMPS appears to be superior for perfusion preservation of myocardium by reducing edema development during storage.

페이스 북
페이지에 가입하세요

과학이 뒷받침하는 가장 완벽한 약초 데이터베이스

  • 55 개 언어로 작동
  • 과학이 뒷받침하는 약초 치료제
  • 이미지로 허브 인식
  • 인터랙티브 GPS지도-위치에 허브 태그 지정 (출시 예정)
  • 검색과 관련된 과학 출판물 읽기
  • 효과로 약초 검색
  • 관심사를 정리하고 뉴스 연구, 임상 실험 및 특허를 통해 최신 정보를 확인하세요.

증상이나 질병을 입력하고 도움이 될 수있는 약초에 대해 읽고 약초를 입력하고 사용되는 질병과 증상을 확인합니다.
* 모든 정보는 발표 된 과학 연구를 기반으로합니다.

Google Play badgeApp Store badge