Korean
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Scandinavian Journal of Clinical and Laboratory Investigation 2019-May

Influence of hemolysis on clinical chemistry parameters determined with Beckman Coulter tests - detection of clinically significant interference.

등록 된 사용자 만 기사를 번역 할 수 있습니다.
로그인 / 가입
링크가 클립 보드에 저장됩니다.
Antonija Perović
Maja Dolčić

키워드

요약

The aim of this study was to examine the influence of hemolysis on 25 clinical chemistry parameters and to compare the resulting bias with clinically significant differences and the manufacturer's specifications. Using freeze-thawing of the treated blood aliquot of each subject (N = 17), four hemolysis levels were prepared with hemolysis index (HI) and hemoglobin concentration as follows: (+)=0.5-0.99 g/L, (2+)=1-1.99 g/L, (3+)=2-2.99 g/L and (4+)=3-4.99 g/L. All analytes were tested on the Beckman Coulter AU480 analyzer using proprietary reagents. It was considered that the interference was detected if the 95% confidence interval for mean differences (%) between hemolyzed and non-hemolyzed samples did not include zero. Clinically significant interference was judged against reference change value (RCV). Hemolysis interference was detected for: alpha-amylase, alkaline phosphatase (ALP), aspartate aminotransferase (AST), total and conjugated bilirubin, creatine kinase (CK), CK-MB, ɣ-glutamyltransferase (GGT), iron, lactate dehydrogenase (LD), magnesium, potassium, total protein and uric acid at HI=(1+); alanine aminotransferase (ALT) and phosphate at HI=(2+); urea at HI=(3+); albumin and cholinesterase at HI=(4+). Even at the greatest hemolysis degree, HI=(4+), no interference was detected for calcium, chloride, creatinine, C-reactive protein (CRP), glucose and sodium. Clinically significant difference was exceeded for LD at HI=(1+); CK-MB at HI=(2+); AST and potassium at HI=(3+); total bilirubin at HI=(4+). The presented results did not support the manufacturer's claim for CK and GGT. Establishing HI thresholds for reporting or suppressing test results is the responsibility of each laboratory, taking into account the manufacturer's data, but also its own investigations.

페이스 북
페이지에 가입하세요

과학이 뒷받침하는 가장 완벽한 약초 데이터베이스

  • 55 개 언어로 작동
  • 과학이 뒷받침하는 약초 치료제
  • 이미지로 허브 인식
  • 인터랙티브 GPS지도-위치에 허브 태그 지정 (출시 예정)
  • 검색과 관련된 과학 출판물 읽기
  • 효과로 약초 검색
  • 관심사를 정리하고 뉴스 연구, 임상 실험 및 특허를 통해 최신 정보를 확인하세요.

증상이나 질병을 입력하고 도움이 될 수있는 약초에 대해 읽고 약초를 입력하고 사용되는 질병과 증상을 확인합니다.
* 모든 정보는 발표 된 과학 연구를 기반으로합니다.

Google Play badgeApp Store badge