Korean
Albanian
Arabic
Armenian
Azerbaijani
Belarusian
Bengali
Bosnian
Catalan
Czech
Danish
Deutsch
Dutch
English
Estonian
Finnish
Français
Greek
Haitian Creole
Hebrew
Hindi
Hungarian
Icelandic
Indonesian
Irish
Italian
Japanese
Korean
Latvian
Lithuanian
Macedonian
Mongolian
Norwegian
Persian
Polish
Portuguese
Romanian
Russian
Serbian
Slovak
Slovenian
Spanish
Swahili
Swedish
Turkish
Ukrainian
Vietnamese
Български
中文(简体)
中文(繁體)
Analytical Chemistry 2000-Jun

Quantification of lanthanides in rocks using succinic acid-derivatized sorbents for on-line SPE-RP-ion-pair HPLC

등록 된 사용자 만 기사를 번역 할 수 있습니다.
로그인 / 가입
링크가 클립 보드에 저장됩니다.
Buchmeiser
Seeber
Tessadri

키워드

요약

The use of new poly(norbornene-block-7-oxanorborn-2ene-5,6-dicarboxylic acid)-coated silica-based sorbents as well as of beaded polymers based on poly(norborn-2-ene-5,6-dicarboxylic acid-co-1,4,4a,5,8,8a-hexahydro-1,4,5,8-exo-endo-dimethanonaphthalene) for the on-line preconcentration of lanthanides from rock digests and their subsequent RP-ion-pair HPLC separation is described. Block co-polymers of norborn-2-ene and 7-oxanorborn-2-ene-5,6-dicarboxylate used for coating were prepared by ring-opening metathesis polymerization (ROMP) and poly(norborn-2-ene-5,6-dicarboxylic acid-co-1,4,4a,5,8,-8a-hexahydro-1,4,5,8-exo-endo-dimethanonaphthalene)-based polymer beads were prepared by ring-opening metathesis precipitation polymerization. Both types of sorbents exhibit an extraordinarily good pH stability, are hydrophilic and therefore easily wetable by water alone, and show high extraction efficiencies for lanthanides within a pH of 3.5-5.5. The rare earth element (REE) content in the investigated rocks varied over 3 orders of magnitude (0.19-108 microg/g). REE concentrations prior to enrichment were typically in the range of 1-25 ng/mL; the total amount of each REE sorbed onto the precolumn was in the range of 8-270 ng. Extraction selectivities of the sorbent may be enhanced by adding 5-sulfosalicylic acid as a masking agent for iron and aluminum as well as methanol as an inhibitor for the precipitation of o-silicic acid. Gradient elution of the lanthanides from the precolumn and their subsequent separation on a RP-C18 column was achieved using hydroxyisobutyric acid (HIBA) and sodium octanesulfonate. Depending on the actual concentration of the lanthanides in the digests and in order to suppress interfering cations, UV detection was carried out with two different postderivatization reagents, 4-(2-pyridylazo)resorcinol (PAR) and arsenazo III. The high selectivity in enrichment as well as the complementary use of post-derivatization reagents allows the fast, quantitative, and highly reproducible quantification of REEs present in rocks by complete removal or suppression of all other interfering components. Thus, recoveries were found to be within a range of 97-103% for most REEs with relative standard deviations of 2-5%.

페이스 북
페이지에 가입하세요

과학이 뒷받침하는 가장 완벽한 약초 데이터베이스

  • 55 개 언어로 작동
  • 과학이 뒷받침하는 약초 치료제
  • 이미지로 허브 인식
  • 인터랙티브 GPS지도-위치에 허브 태그 지정 (출시 예정)
  • 검색과 관련된 과학 출판물 읽기
  • 효과로 약초 검색
  • 관심사를 정리하고 뉴스 연구, 임상 실험 및 특허를 통해 최신 정보를 확인하세요.

증상이나 질병을 입력하고 도움이 될 수있는 약초에 대해 읽고 약초를 입력하고 사용되는 질병과 증상을 확인합니다.
* 모든 정보는 발표 된 과학 연구를 기반으로합니다.

Google Play badgeApp Store badge